Message Overview:
Message Name:
HYD 3 PRESSURE INDICATION
| Message Code: | 293OBS007 |
| Effectivity: | All |
| System: | Engine Indicating |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Data Acquisition Unit (DAU) 3 is reporting Hydraulic System 3 pressure incorrectly, erratically or dashed.
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Hydraulic System 3 Pressure Transducer (MT146)
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hydraulic Pressure Transducers | AMM 29-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hydraulic Pressure Transducers | AMM 29-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Hydraulic System 3 Pressure Transducer (MT146) with Hydraulic System 1 Pressure Transducer (MT140).
- If system checks are good, replace Hydraulic System 3 Pressure Transducer and do close out.
- If fault remains, continue with next step.
- Swap DAU 3 with DAU 4.
- If system checks are good, replace DAU 3 and do close out.
- If fault remains, continue with next step.
- Perform wiring check between DAU 3, Hydraulic Pressure Transducer 3 (MT146), and SPDA 3.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform voltage check as follows:
Hydraulic System 3
Pressure TransducerExpected Result MT146P1-D 28 VDC - If there is 28 VDC, do close out.
- If there is no 28 VDC, continue with next step.
- Replace SPDA 3.
- Do close out.