06/29/21
Message Overview:
Message Name:
HYDRAULIC QUANTITY INDICATION INVALID
| Message Code: | 293OBS014 |
| Effectivity: | All |
| System: | Hydraulic System |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-12-00 [ Global Express ] [ G5000 ] [ Global XRS ] 29-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
On the Engine Indication and Crew Alerting System (EICAS) Hydraulic Synoptic Page (HSP), the Hydraulic Quantity Indication is in error.
Possible Causes:
- Data Acquisition Unit (DAU) 1 (A17)
- Data Acquisition Unit (DAU) 2 (A18)
- Data Acquisition Unit (DAU) 3 (A30)
- Data Acquisition Unit (DAU) 4 (A31)
- Hydraulic-System 1 Reservoir Quantity Transducer (MT139)
- Hydraulic-System 2 Reservoir Quantity Transducer (MT142)
- Hydraulic-System 3 Reservoir Quantity Transducer (MT145)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Hydraulic Safety Precautions | AMM 29-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Hydraulic Technical Precautions | AMM 29-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the No. 1 and No. 2 Hydraulic System Reservoirs | AMM 29-12-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the No. 1 and No. 2 Hydraulic System Reservoirs | AMM 29-12-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the No. 3 Hydraulic System Reservoir | AMM 29-13-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the No. 3 Hydraulic System Reservoir | AMM 29-13-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check the INVALID hydraulic quantity indication is on the hydraulic quantity-transducer 1, 2 or 3.
- If hydraulic quantity indication 1 is invalid, continue with the next step.
- If hydraulic quantity indication 2 is invalid, go to step 7.
- If hydraulic quantity indication 3 is invalid, go to step 12.
- Disconnect the connector MT139P1 from the hydraulic quantity-transducer 1. Perform a voltage check within hydraulic quantity-transducer 1 as follows:
From To Expected Result Result MT139P1-A MT139P1-B 11±1 VDC - If there is 11±1 VDC, go to step 4.
- If there is no 11±1 VDC, continue with the next step.
- Remove the DAU 1 to get access to connector A17BP1. Perform a continuity check for an open circuit or a short circuit to ground between the Hydraulic-Quantity Transducer 1 (MT139P1) and DAU 1 (A17BP1) that follows:
From To Result MT139P1-A A17BP1-G3 MT139P1-B A17BP1-J3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check for an open circuit or a short circuit to ground between the Hydraulic-Quantity Transducer 1 (MT139P1) and DAU 1 (A17BP1) that follow:
From To Result MT139P1-D A17BP1-H3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a check for resistance within Hydraulic-Quantity Transducer 1 (MT139P1) as follows:
From To Expected Result Result MT139P1-A MT139P1-D more than 37 Ω but less than 566 Ω MT139P1-B MT139P1-D more than 37 Ω but less than 566 Ω - If resistance value is out of limit, replace the hydraulic-system reservoir 1 and do close out.
- If resistance value is within limit, continue with the next step.
- Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 1 (MT139P1) as follows:
From To Result MT139P1-A Ground MT139P1-B Ground MT139P1-D Ground - If there is continuity, replace the hydraulic-system reservoir 1 and do close out.
- If there is no continuity, continue with the next step.
- Disconnect the connector MT142P1 from the hydraulic quantity-transducer 2. Perform a voltage check within hydraulic quantity-transducer 2 as follows:
From To Expected Result Result MT142P1-A MT142P1-B 11±1 VDC - If there is 11±1 VDC, go to step 9.
- If there is no 11±1 VDC, continue with the next step.
- Remove the DAU 2 to get access to connector A18BP1. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 2 (MT142P1) and DAU 2 (A18BP1) that follows:
From To Result MT142P1-A A18BP1-G3 MT142P1-B A18BP1-J3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 2 (MT142P1) and DAU 2 (A18BP1) that follow:
From To Result MT142P1-D A18BP1-H3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a check for resistance between within Hydraulic-Quantity Transducer 2 as follows:
From To Expected Result Result MT142P1-A MT142P1-D more than 37 Ω but less than 566 Ω MT142P1-B MT142P1-D more than 37 Ω but less than 566 Ω - If resistance value is out of limit, replace the hydraulic-system reservoir 2 and do close out.
- If resistance value is within limit, continue with the next step.
- Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 2 (MT142P1) as follows:
From To Result MT142P1-A Ground MT142P1-B Ground MT142P1-D Ground - If there is continuity, replace the hydraulic-system reservoir 2 and do close out.
- If there is no continuity, continue with the next step.
- Disconnect the connector MT145P1 from the 3 hydraulic quantity-transducer. Perform a voltage check within hydraulic quantity-transducer 3 as follows:
From To Expected Result Result MT145P1-A MT145P1-B 11±1 VDC - If there is 11±1 VDC, go to step 14.
- If there is no 11±1 VDC, continue with the next step.
- Remove the DAU 3 to get access to connector A30BP1. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 3 (MT145P1) and DAU 3 (A30BP1) that follows:
From To Result MT145P1-A A30BP1-G3 MT145P1-B A30BP1-J3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 3 (MT145P1) and DAU 3 (A30BP1) that follows:
From To Result MT145P1-D A30BP1-H3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a check for resistance within the within Hydraulic-Quantity Transducer 3 as follows:
From To Expected Result Result MT145P1-A MT145P1-D more than 37 Ω but less than 566 Ω MT145P1-B MT145P1-D more than 37 Ω but less than 566 Ω - If resistance value is out of limit, go to step 17.
- If resistance value is within limit, continue with the next step.
- Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 3 (MT145P1) as follows:
From To Result MT145P1-A Ground MT145P1-B Ground MT145P1-D Ground - If there is no continuity, do close out.
- If there is continuity, continue with the next step.
- Replace Hydraulic System Reservoir 3.
- Do close out.