Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/29/21

Message Overview:

Message Name:

HYDRAULIC QUANTITY INDICATION INVALID

Message Code: 293OBS014
Effectivity: All
System: Hydraulic System
System Description: 29-30-00
Schematic Diagram: 29-12-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
29-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 29-00-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

On the Engine Indication and Crew Alerting System (EICAS) Hydraulic Synoptic Page (HSP), the Hydraulic Quantity Indication is in error.

Possible Causes:

  • Data Acquisition Unit (DAU) 1 (A17)
  • Data Acquisition Unit (DAU) 2 (A18)
  • Data Acquisition Unit (DAU) 3 (A30)
  • Data Acquisition Unit (DAU) 4 (A31)
  • Hydraulic-System 1 Reservoir Quantity Transducer (MT139)
  • Hydraulic-System 2 Reservoir Quantity Transducer (MT142)
  • Hydraulic-System 3 Reservoir Quantity Transducer (MT145)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Hydraulic Safety Precautions AMM 29-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Hydraulic Technical Precautions AMM 29-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the No. 1 and No. 2 Hydraulic System Reservoirs AMM 29-12-25-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the No. 1 and No. 2 Hydraulic System Reservoirs AMM 29-12-25-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the No. 3 Hydraulic System Reservoir AMM 29-13-29-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the No. 3 Hydraulic System Reservoir AMM 29-13-29-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check the INVALID hydraulic quantity indication is on the hydraulic quantity-transducer 1, 2 or 3.

    1. If hydraulic quantity indication 1 is invalid, continue with the next step.
    2. If hydraulic quantity indication 2 is invalid, go to step 7.
    3. If hydraulic quantity indication 3 is invalid, go to step 12.

  2. Disconnect the connector MT139P1 from the hydraulic quantity-transducer 1. Perform a voltage check within hydraulic quantity-transducer 1 as follows:

    From To Expected Result Result
    MT139P1-A MT139P1-B 11±1 VDC

    1. If there is 11±1 VDC, go to step 4.
    2. If there is no 11±1 VDC, continue with the next step.

  3. Remove the DAU 1 to get access to connector A17BP1. Perform a continuity check for an open circuit or a short circuit to ground between the Hydraulic-Quantity Transducer 1 (MT139P1) and DAU 1 (A17BP1) that follows:

    From To Result
    MT139P1-A A17BP1-G3
    MT139P1-B A17BP1-J3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  4. Perform a continuity check for an open circuit or a short circuit to ground between the Hydraulic-Quantity Transducer 1 (MT139P1) and DAU 1 (A17BP1) that follow:

    From To Result
    MT139P1-D A17BP1-H3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  5. Perform a check for resistance within Hydraulic-Quantity Transducer 1 (MT139P1) as follows:

    From To Expected Result Result
    MT139P1-A MT139P1-D more than 37 Ω but less than 566 Ω
    MT139P1-B MT139P1-D more than 37 Ω but less than 566 Ω

    1. If resistance value is out of limit, replace the hydraulic-system reservoir 1 and do close out.
    2. If resistance value is within limit, continue with the next step.

  6. Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 1 (MT139P1) as follows:

    From To Result
    MT139P1-A Ground
    MT139P1-B Ground
    MT139P1-D Ground

    1. If there is continuity, replace the hydraulic-system reservoir 1 and do close out.
    2. If there is no continuity, continue with the next step.

  7. Disconnect the connector MT142P1 from the hydraulic quantity-transducer 2. Perform a voltage check within hydraulic quantity-transducer 2 as follows:

    From To Expected Result Result
    MT142P1-A MT142P1-B 11±1 VDC

    1. If there is 11±1 VDC, go to step 9.
    2. If there is no 11±1 VDC, continue with the next step.

  8. Remove the DAU 2 to get access to connector A18BP1. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 2 (MT142P1) and DAU 2 (A18BP1) that follows:

    From To Result
    MT142P1-A A18BP1-G3
    MT142P1-B A18BP1-J3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  9. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 2 (MT142P1) and DAU 2 (A18BP1) that follow:

    From To Result
    MT142P1-D A18BP1-H3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  10. Perform a check for resistance between within Hydraulic-Quantity Transducer 2 as follows:

    From To Expected Result Result
    MT142P1-A MT142P1-D more than 37 Ω but less than 566 Ω
    MT142P1-B MT142P1-D more than 37 Ω but less than 566 Ω

    1. If resistance value is out of limit, replace the hydraulic-system reservoir 2 and do close out.
    2. If resistance value is within limit, continue with the next step.

  11. Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 2 (MT142P1) as follows:

    From To Result
    MT142P1-A Ground
    MT142P1-B Ground
    MT142P1-D Ground

    1. If there is continuity, replace the hydraulic-system reservoir 2 and do close out.
    2. If there is no continuity, continue with the next step.

  12. Disconnect the connector MT145P1 from the 3 hydraulic quantity-transducer. Perform a voltage check within hydraulic quantity-transducer 3 as follows:

    From To Expected Result Result
    MT145P1-A MT145P1-B 11±1 VDC

    1. If there is 11±1 VDC, go to step 14.
    2. If there is no 11±1 VDC, continue with the next step.

  13. Remove the DAU 3 to get access to connector A30BP1. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 3 (MT145P1) and DAU 3 (A30BP1) that follows:

    From To Result
    MT145P1-A A30BP1-G3
    MT145P1-B A30BP1-J3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  14. Perform a continuity check for an open circuit or a short circuit to ground between Hydraulic-Quantity Transducer 3 (MT145P1) and DAU 3 (A30BP1) that follows:

    From To Result
    MT145P1-D A30BP1-H3

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with the next step.

  15. Perform a check for resistance within the within Hydraulic-Quantity Transducer 3 as follows:

    From To Expected Result Result
    MT145P1-A MT145P1-D more than 37 Ω but less than 566 Ω
    MT145P1-B MT145P1-D more than 37 Ω but less than 566 Ω

    1. If resistance value is out of limit, go to step 17.
    2. If resistance value is within limit, continue with the next step.

  16. Perform a continuity check for a short circuit to ground within Hydraulic-Quantity Transducer 3 (MT145P1) as follows:

    From To Result
    MT145P1-A Ground
    MT145P1-B Ground
    MT145P1-D Ground

    1. If there is no continuity, do close out.
    2. If there is continuity, continue with the next step.

  17. Replace Hydraulic System Reservoir 3.
  18. Do close out.