Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/29/21

Message Overview:

Message Name:

HYDRAULIC TEMPERATURE TRANSDUCERS INVALID OR INCORRECT

Message Code: 293OBS017
Effectivity: All
System: Engine Indicating
System Description: 29-30-00
Schematic Diagram: 29-12-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
29-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 29-00-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The fault isolation procedures that follow are for the Hydraulic System Temperature Transducers 1, 2 and 3. Differences are identified.

Possible Causes:

  • Hydraulic System 1 Reservoir Temperature Transducer (MT138)
  • Hydraulic System 2 Reservoir Temperature Transducer (MT141)
  • Hydraulic System 3 Reservoir Temperature Transducer (MT144)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Hydraulic Safety Precautions AMM 29-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Hydraulic Technical Precautions AMM 29-00-00-910-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Hydraulic Temperature Transducers AMM 29-33-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Hydraulic Temperature Transducers AMM 29-33-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Disconnect the affected hydraulic-system temperature-transducer MT138P1 for 1, MT141P1 for 2 or MT144P1 for 3. Perform a check for the resistance within applicable Temperature Transducer as follows:
    NOTE: The resistance must be between 67.77 Ω and 244.20 Ω.

    From To Expected Result Result
    MT138P1-A MT138P1-B 67.77 Ω - 244.20 Ω
    MT141P1-A MT141P1-B 67.77 Ω - 244.20 Ω
    MT144P1-A MT144P1-B 67.77 Ω - 244.20 Ω

    1. If the resistance is incorrect, replace the defective Temperature Transducer and do close out.
    2. If the resistance is correct, continue with the next step.

  2. Check if the system fluid-temperature is hotter than the ambient temperature.

    1. If the system fluid-temperature is hotter, record the temperature at the top of the reservoir surface near the temperature transducer.
    2. If the system fluid-temperature is cold, or at ambient temperature, record the ambient temperature.

  3. Measure and record the resistance between the pins A and B of the transducer connector. Use the table that follows to find the correct value and tolerance:

    Fluid Temperature Measured Resistance
    14°F (-10°C) 87.04±0.40 Ω
    32°F (32°C) 90.38±0.40 Ω
    50°F (10°C) 93.80±0.40 Ω
    68°F (20°C) 97.31±0.40 Ω
    86°F (30°C) 100.91±0.40 Ω
    104°F (40°C) 104.60±0.40 Ω
    122°F (50°C) 108.39±0.40 Ω
    140°F (60°C) 112.28±0.50 Ω
    158°F (70°C) 116.27±0.50 Ω
    176°F (80°C) 120.36±0.50 Ω
    194°F (90°C) 124.55±0.50 Ω
    212°F (100°C) 128.85±0.50 Ω
    230°F (110°C) 133.26±0.50 Ω

    1. If the resistance is satisfactory, do close out.
    2. If the resistance is not satisfactory, continue with the next step.

  4. Replace the Defective Temperature Transducer.
  5. Do close out.