Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/30/21

Message Overview:

Message Name:

HYDRAULIC SYSTEM 2 BRAKE ACCUMULATOR BLEED DOWN TEST FAILS

Identifier: 324OBS004
Effectivity: ALL
System: Brake Control System
Effectivity: All
System Description: 32-43-00
Schematic Diagram: 32-43-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 32-43-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Brake Accumulator 2 fails the bleed down test (AMM 32-43-37-720-801).

Possible Causes:

  • Outboard Brake Shutoff Valve (L14)
  • Brake accumulator

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Brake Shutoff Valve AMM 32-43-25-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Brake Shutoff Valve AMM 32-43-25-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the No.2 Brake Accumulator AMM 32-43-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the No.2 Brake Accumulator AMM 32-43-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Functional Test of the No. 2 Brake Accumulator AMM 32-43-37-720-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Release the pressure from hydraulic system 2.
  2. Disconnect the "PRESS" line at the No. 2 brake Shutoff Valve (SOV).
  3. Install a cap on the "PRESS" line at the No. 2 brake SOV.
  4. Pressurize hydraulic system 2.
  5. Shut down the source of hydraulic power.
  6. After 1 hour, does the pressure on the accumulator gauge decrease below 2090 psi (14,411 kPa) or below 1080 psi (7,447 kPa) after 2 hours?
    NOTE: If the pressure decreases more than 50 psi (345 kPa) in two to four minutes, do not wait one hour and continue with next step.

    1. If YES, continue with next step.
    2. If NO, replace the No. 2 brake SOV.

  7. Look for hydraulic fluid external leakage. Rectify as required.
  8. If no external leakage is found, replace the No. 2 Brake Accumulator.
  9. Do close out