Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/30/21

Message Overview:

Message Name:

COCKPIT LIGHTS (FLOOD/DISPLAY) CONTROL PANEL DO NOT COME ON

Message Code: 331OBS001
Effectivity: All
System: Miscellaneous Lighting
System Description: 33-13-00
Schematic Diagram: 33-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
33-13-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

A group or groups of Floodlights or Electronic Flight-Instrument System/Engine Indication and Crew Alerting System (EFIS/EICAS) and/or Electrical Management System Control-and-Display Unit (EMS CDU) Display Lights do not come on. Light Bulbs are serviceable. The Light Control Panel does not control intensity of a group or some groups of lights.

Possible Causes:

  • Light Switch or Control
  • Cockpit Lights (Flood/Display) Control Panel (AP27)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the COCKPIT LIGHTS (FLOOD/DISPLAY)
Control Panel
AMM 33-13-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the COCKPIT LIGHTS (FLOOD/DISPLAY)
Control Panel
AMM 33-13-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the COCKPIT LIGHTS (FLOOD/DISPLAY)
Control Panel
AMM 33-13-33-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check if a DIM/BRT or OFF/BRT rotary switch changes the intensity of a group of lights.

    1. If DIM/BRT or OFF/BRT rotary switch does not change the intensity of a group of lights, go to step 5.
    2. If DIM/BRT or OFF/BRT rotary switch change the intensity of a group of lights, continue with next step.

  2. Perform the operational test of the COCKPIT LIGHTS (FLOOD/DISPLAY) control panel.

    1. If the test is satisfactory, do close out.
    2. If the test is unsatisfactory, continue with next step.

  3. Disconnect the connectors (AP27P1 or AP27P2) from the control panel AP27. Perform a voltage check as follows:
    For a floodlight problem (+28 VDC):

    From To Result
    AP27P2-16 GROUND

    For a DU 1 (L) lighting problem:

    From To Result
    AP27P1-5 AP27P1-7
    AP27P1-6 AP27P1-7

    For a DU 2 (L) lighting problem:

    From To Result
    AP27P2-5 AP27P2-7
    AP27P2-6 AP27P2-7

    For an EMS CDU 1 (L) lighting problem:

    From To Result
    AP27P1-21 AP27P1-22
    AP27P1-15 AP27P1-22

    For a DU 3 (CTR) lighting problem:

    From To Result
    AP27P1-8 AP27P1-10
    AP27P1-9 AP27P1-10

    For a DU 4 (CTR) lighting problem:

    From To Result
    AP27P2-8 AP27P2-10
    AP27P2-9 AP27P2-10

    For a DU 5 (R) lighting problem:

    From To Result
    AP27P1-11 AP27P1-13
    AP27P1-12 AP27P1-13

    For a DU 6 (R) lighting problem:

    From To Result
    AP27P2-11 AP27P2-13
    AP27P2-12 AP27P2-13

    For an EMS CDU 2 (R) lighting problem:

    From To Result
    AP27P2-21 AP27P2-22
    AP27P2-15 AP27P2-22

    1. If there is volatge, go to step 5.
    2. If there is no volatge, continue with next step.

  4. Perform a continuity check at the connectors AP27P1 or AP27P2 as follows:
    For a L floodlight problem:

    From To Result
    AP27P1-17 GROUND
    AP27P1-18 GROUND

    For a CTR floodlight problem:

    From To Result
    AP27P1-16 GROUND

    For a R floodlight problem:

    From To Result
    AP27P2-17 GROUND
    AP27P2-18 GROUND

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  5. Replace COCKPIT LIGHTS (FLOOD/DISPLAY) control panel.
  6. Connect the disconnected connectors to the flood light control panel (AP27).
  7. If the problem continues, perform the troubleshooting for CAS Message ELEC SYS FAIL (Amber) and ELEC SYS FAULT (Cyan).
  8. Do close out.