06/30/21
Message Overview:
Message Name:
NO SMOKING SWITCH IS SET TO ON BUT SIGN IS OFF
| Message Code: | 332OBS001 |
| Effectivity: | All |
| System: | Cabin Sign/Emergency Light Panel |
| System Description: | 33-20-00 |
| Schematic Diagram: | 33-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 33-51-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
No smoking sign is not on and No Smoking switch is set to ON.
Possible Causes:
- Cabin Sign/Emergency Light Panel (AP13)
- No Smoking Switch (S2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the PASS SIGNS/EMER LIGHTS Control Panel | AMM 33-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the PASS SIGNS/EMER LIGHTS Control Panel | AMM 33-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check light bulb.
- If fault remains, repair or replace as required and do close out.
- If system checks are good, continue with next step.
- Perform wiring checks between NO SMKG switch and EMS CDU(s).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace PASS SIGNS/EMER LIGHTS Control Panel.
- Do close out.