Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/30/21

Message Overview:

Message Name:

FAILURE INDICATOR BOX-AUTOMATIC SECONDARY LIGHT SELECTION IS UNSERVICEABLE

Message Code: 334OBS003
Effectivity: All
System: Navigation Lighting System
System Description: 33-42-00
Schematic Diagram: 33-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 33-42-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Automatic Secondary Light selection does not operate. There is no 28 VDC output from the Failure Indicator Box. There is no failure output to Data Acquisition Unit (DAU) 4.

Possible Causes:

  • Failure Indicator Box (A126)
  • External Lights Control Panel (AP11)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the EXTERNAL LIGHTS Control Panel AMM 33-40-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the EXTERNAL LIGHTS Control Panel AMM 33-40-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Navigation Lighting AMM 33-42-00-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Failure Indicator Box AMM 33-42-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Failure Indicator Box AMM 33-42-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Set the NAV switch to ON.
  2. Measure the voltage at the connector A126P1 as follows:

    From To Result
    A126P1-A A126P1-P

    1. If there is no voltage, repair the defective wiring as required and do close out.
    2. If there is voltage, continue with next step.

  3. Replace the failure indicator box. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Replace the external lights control panel. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  5. Perform troubleshooting procedure for CAS message below. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  6. Perform wiring check between DAU 4 and Failure Indicator Box. Repair as required.
  7. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.