07/01/21
Message Overview:
Message Name:
HEAD-UP-DISPLAY (HUD) COMBINER UNIT IMPROPER OPERATION
| Message Code: | 343OBS001 |
| Effectivity: | Post SB 700-34-002 and 9140 and Subs |
| System: | Head-Up-Display (HUD) System |
| System Description: | 34-32-00 |
| Schematic Diagram: | 34-32-00 [ Global Express ] [ G5000 ] [ GlobalXRS ] |
| Wiring Diagram: | 34-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Head-Up-Display (HUD) Combiner Unit does not show images or does not move correctly or does not stay in the operational, breakaway and stowed positions.
Possible Causes:
- Head-Up-Display (HUD) Combiner Unit (COU) (MT216)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB 700-34-002 - Modification-Head-Up Display System - Installation
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Head-Up-Display (HUD) System |
AMM 34-32-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Head-Up-Display (HUD) Combiner Unit |
AMM 34-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Head-Up-Display (HUD) Combiner Unit |
AMM 34-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Lock the HUD combiner unit in the operational position. Perform the operational test of the HUD system. Does the HUD MISALIGN message show on the EICAS display?
- If YES, perform the troubleshooting for CAS message HUD MISALIGN (Advisory).
- If NO, continue with next step.
- Replace the head-up-display (HUD) combiner unit.
- Do close out.