07/01/21
Message Overview:
Message Name:
GPWS WARNING FAILED DURING ALERT CONDITION
| Message Code: | 344OBS006 |
| Effectivity: | All |
| System: | Enhanced Ground Proximity Warning-System (EGPWS) |
| System Description: | 34-42-00 |
| Schematic Diagram: | 34-42-00 [ Global Express ] [ G5000 ] [ GlobalXRS ] |
| Wiring Diagram: | 34-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Aural and/or the visual warning for the Ground Proximity Warning-System (GPWS) failed to come on during an alert condition.
Possible Causes:
- Enhanced Ground-Proximity Warning System (EGPWS) (A64)
- Audio Panel 1 (A8)
- Audio Panel 2 (A9)
- Data Acquisition Unit (DAU) 3 (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- ISMODSUM IS700-34-0009 rev A - Navigation - EGPWS - Configuration Strapping for Alternate Mode 6 Aural Altitude Callouts
Quick Links:
| Removal of the Audio Panels | AMM 23-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Audio Panels | AMM 23-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Audio Panels | AMM 23-51-05-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Data Acquisition System | AMM 31-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Enhanced Ground-Proximity Warning System (EGPWS) |
AMM 34-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the affected audio panel (A8 or A9) and perform a continuity check between the GPWC connector (A64BP1) and AUDIO PANEL 1 or 2 as follows:
For Pilot's Audio Panel:From To Result A64BP1-C13 A8P2-m A64BP1-D13 A8P2-j A64BP1-SH A8P2-SH For Copilot's Audio Panel:
From To Result A64BP1-C13 A9P2-m A64BP1-D13 A9P2-j A64BP1-SH A9P2-SH - If there is no continuity, repair defective wiring as required and go to step 3.
- If there is continuity, continue with next step.
- Install the audio panel and perform the operational test of the audio panels.
- If the operational test are not satisfactory, perform troubleshooting for "Audio Panel 1" or "Audio Panel 2" and do close out.
- If the operational test are satisfactory, go to step 6.
- Perform the operational test of the GPWS system. Check if the warning GPWS displayed on the PFDs.
- If the warning GPWS is seen on PFDs, do close out.
- If the warning GPWS is not seen on PFDs, continue with next step.
- Remove the DAU 3 (A30) and access connector A30CP1. Perform a continuity check between the pins of the connectors DAU 3 (A30CP1) and GPWC (A64AP1) or (A64BP1) as follows:
From To Result A64AP1-A2 A30CP1-F8 A64AP1-B2 A30CP1-G8 A64AP1-SH A30CP1-SH A64BP1-C1 A30CP1-D7 A64BP1-D1 A30CP1-E7 A64BP1-SH A30CP1-SH - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Install the DAU 3 and perform the operational test of the DAU 3.
- If the operational test are not satisfactory, perform the troubleshooting for CAS message DAU 3A FAIL (Advisory) or DAU 3B FAIL (Advisory) and do close out.
- If the operational test are satisfactory, continue with next step.
- Replace GPWS computer.
- Do close out.