07/01/21
Message Overview:
Message Name:
NO OXYGEN AT CREW MASK
| Message Code: | 351OBS003 |
| Effectivity: | All |
| System: | Crew Oxygen System |
| System Description: | 35-10-00 |
| Schematic Diagram: | 35-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 35-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
There is no oxygen available at a Crew Mask.
Possible Causes:
- Third Crew Oxygen Mask (A217)
- Oxygen Line Pressure Switch (S52)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Oxygen System Safety Precautions | AMM 35-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Crew Oxygen System | AMM 35-10-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Crew Oxygen Masks | AMM 35-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Crew Oxygen Masks | AMM 35-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Set the flow selector lever on the pilot's mask to ON mode, push and hold the PRESS TO TEST AND RESET lever on the stowage box.
- Check if the flow indicator changes to yellow and then black after a short time.
- If YES, release the PRESS TO TEST AND RESET lever on the stowage box and go to step 4.
- If NO, release the PRESS TO TEST AND RESET lever on the stowage box and continue with next step.
- Check that the oxygen line is connected correctly.
- If the oxygen line is connected correctly, go to step 7.
- If the oxygen line is not connected correctly, connect the line correctly and do close out.
- Perform the check of the oxygen mask as follows:
- Carefully remove the mask from the stowage box
- Put the oxygen mask on your face
- Close the stowage box to monitor the indicator
- Set the flow selector on the mask regulator to ON mode
- check if the indicator changes to yellow when you breathe and change to black when you stop
- If the indicator does not change to yellow and black when breathing, go to step 7.
- If the indicator changes to yellow and black when breathing, continue with next step.
- Set the flow selector on the mask regulator to 100% and check if the indicator change to yellow when you breathe and change to black when you stop.
- If the indicator does not change to yellow and black when breathing, go to step 7.
- If the indicator changes to yellow and black when breathing, continue with next step.
- Turn the PRESS TO TEST Control Knob counterclockwise to the EMERGENCY position. Check if the oxygen flows continuously.
- If the oxygen flows continuously, do close out.
- If the oxygen does not flow continuously, continue with next step.
- Replace Crew Oxygen Mask.
- Do close out.