07/02/21
Message Overview:
Message Name:
CBV FAILED IN CLOSED POSITION
| Message Code: | 361OBS001 |
| Effectivity: | All |
| System: | Bleed Air System |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Cross Bleed Valve failed in the closed position.
Possible Causes:
- Secondary Power Distribution Assemblies (SPDA) 3 (A15)
- Cross Bleed Valve (L35)
- Junction Box (K15/JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Cross-Bleed Valve | AMM 36-11-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cross-Bleed Valve | AMM 36-11-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the BLEED AIR control panel, set the XBLEED switch to the OPEN position.
- Measure for 28 VDC at CBV L35P1-4.
- If no 28 VDC, repair or replace the defective wiring as required and do close out.
- If there is 28 VDC, continue with next step.
- Perform wiring checks between SPDA 3, JB4, CBV and GS423.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
NOTE: Remove all interface components for short circuit test.
- Swap SPDA 3 with SPDA 1.
- If system checks are good, replace SPDA 3 and do close out.
- If fault remains, continue with next step.
- Replace CBV.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Junction Box JB4 (K15/JB4).
- Do close out.