Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/02/21

Message Overview:

Message Name:

CBV MECHANICALLY FAILED CLOSED WITH OPEN POSITION INDICATION ON EICAS

Message Code: 361OBS004
Effectivity: All
System: Bleed Air System
System Description: 36-11-00
Schematic Diagram: 36-11-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 30-11-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The Cross Bleed Valve mechanically failed closed with a open position indication on the Engine Indication and Crew Alerting System (EICAS).

Possible Causes:

  • Cross Bleed Valve (L35)
  • Junction Box (PCB3/JB4)
  • Bleed Management Controller (BMC) 1 (A69)
  • Bleed Management Controller (BMC) 2 (A70)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  • When CBV is fully closed, CBV L35P1-5 provides a ground signal (CBV L35 pins 6 and 5 are shorted) to BMCs
  • When CBV is fully open, CBV L35P1-1 provides a ground signal (CBV L35 pins 6 and 1 are shorted) to BMCs
  • CBV L35P1-6 is connected to Ground Stud GS423 to provide the ground signal for fully closed/fully open to BMCs

Quick Links:

Removal of the Junction Box JB4 AMM 24-00-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB4 AMM 24-00-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Cross-Bleed Valve AMM 36-11-29-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Cross-Bleed Valve AMM 36-11-29-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Cross-Bleed Valve AMM 36-11-29-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Bleed Management Controller AMM 36-11-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Bleed Management Controller AMM 36-11-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Manually open CBV.

    1. If CBV cannot be opened, go to step 3.
    2. If CBV open and EICAS show fully open, continue with next step.

  2. Perform a CBV operational test.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Replace CBV.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Perform wiring checks between BMC 1, BMC 2, JB4, CBV and GS423.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.
      NOTE: Remove all interface components for short test.

  5. Replace BMC 1.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Replace BMC 2.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  7. Replace Junction Box JB4 (PCB3/JB4).
  8. Do close out.