07/02/21
Message Overview:
Message Name:
CBV MECHANICALLY FAILED OPEN WITH CLOSED POSITION INDICATION ON EICAS
| Message Code: | 361OBS006 |
| Effectivity: | All |
| System: | Bleed Air System |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Cross Bleed Valve mechanically failed open with a closed position indication on the Engine Indication and Crew Alerting System (EICAS).
Possible Causes:
- Cross Bleed Valve (L35)
- Junction Box (PCB3/JB4)
- Bleed Management Controller (BMC) 1 (A69)
- Bleed Management Controller (BMC) 2 (A70)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- When CBV is fully closed, CBV L35P1-5 provides a ground signal (CBV L35 pins 6 and 5 are shorted) to BMCs
- When CBV is fully open, CBV L35P1-1 provides a ground signal (CBV L35 pins 6 and 1 are shorted) to BMCs
- CBV L35P1-6 is connected to Ground Stud GS423 to provide the ground signal for fully closed/fully open to BMCs
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Cross-Bleed Valve | AMM 36-11-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cross-Bleed Valve | AMM 36-11-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Cross-Bleed Valve | AMM 36-11-29-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Manually close CBV.
- If CBV cannot be closed, go to step 3.
- If CBV closed and EICAS show fully closed, continue with next step.
- Perform a CBV operational test.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace CBV.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between BMC 1, BMC 2, JB4, CBV and GS423.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
NOTE: Remove all interface components for short test.
- Replace BMC 1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace BMC 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Junction Box JB4 (PCB3/JB4).
- Do close out.