Message Overview:
Message Name:
LEFT INTERMEDIATE PRESSURE TRANSDUCER OUTPUT IS OUT OF RANGE
| Message Code: | 361OBS010 |
| Effectivity: | All |
| System: | Bleed Air System |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-11-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Intermediate-Pressure Transducer output is not between 0.02 and 9.9 VDC.
Possible Causes:
- Intermediate-Pressure Transducer
- Junction Box 3 (JB3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Intermediate-Pressure Transducer | AMM 36-11-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Intermediate-Pressure Transducer | AMM 36-11-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Intermediate-Pressure Transducer | AMM 36-11-37-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of the Cowls | AMM 71-10-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of the Cowls | AMM 71-10-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect the electrical connector P734 on the intermediate-pressure transducer. Perform the voltage check as follows:
From To Expected Result Result P734-A P734-B 28 VDC - If the voltage is not as specified, go to step 4.
- If the voltage is as specified, continue with next step.
- Connect the electrical connector P734 to the intermediate-pressure transducer. Disconnect the electrical connector A69P1 from BMC 1. Perform the voltage check as follows:
From To Expected Result Result A69P1-2 A69P1-3 0.02-9.9 VDC - If the voltage is more than 9.9 VDC, replace the left intermediate-pressure transducer and do close out.
- If the voltage is less than 0.02 VDC, continue with next step.
- Disconnect the electrical connector P734 from the intermediate-pressure transducer. Perform a continuity check between the connectors Left IPT (P734) and BMC 1 (A69P1) as follows:
From To Result P734-C A69P1-2 P734-D A69P1-3 - If there is no continuity, repair defective wiring as required and continue with next step.
- If there is continuity, replace the left intermediate-pressure transducer and continue with next step.
- Perform a continuity check as follows:
From To Result P734-B GS263 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Disconnect the electrical connector P625. Perform the voltage check as follows:
From To Result J625-D Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Disconnect the JB3 electrical connector JB3AP1. Perform a continuity check between J625 pin D and JB3AP1 pin 11C.
From To Result J625-D JB3AP1-11C - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace the PCB2 in the junction box JB3.
- Do close out.