Message Overview:
Message Name:
RIGHT BLEED PRESSURE TRANSDUCER INPUT IS TOO LOW
| Message Code: | 361OBS011 |
| Effectivity: | All |
| System: | Bleed Air System |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-11-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Right Bleed Pressure Transducer input is too low.
Possible Causes:
- Auxiliary Power Unit (APU)
- Right Sense Line
- Right Bleed Pressure Transducer (BPT) (MT112)
- Right Bleed Management Controller (BMC) (A70)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Pressure Transducer | AMM 36-11-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Pressure Transducer | AMM 36-11-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Starting the APU | AMM 49-10-00-866-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| APU Shutdown (Normal) | AMM 49-10-00-866-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the BLEED AIR control panel, set the switches as follow:
Reference Position/Indication XBLEED OPEN L PACK OFF R PACK OFF ANTI-ICE WING OFF APU BLEED ON L ENG BLEED OFF R ENG BLEED OFF - Start the APU.
- Use the leak detector solution to perform a leak check at the two end connections of the sense line.
- If there is no leak, go to step 6.
- If a leak is detected, continue with next step.
NOTE: Bubbles or foam in the leak detection solution is an indication of a leak.
- Shutdown the APU and tighten the connection with the leak.
- Start the APU and perform the leak check again.
- If no leak is detected, do close out.
- If a leak is detected, continue with next step.
- Replace the sense line or unions as necessary. Is the leak still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap Right BPT with Left BPT.
- If the system checks are good, replace right BPT and do close out.
- If fault remains, continue with next step.
- Replace Right BMC.
- Do close out.