Message Overview:
Message Name:
ENVIROVAC TOILET WILL NOT FLUSH
| Message Code: | 383OBS001 |
| Effectivity: | Global XRS Global 5000 |
| System: | Water/Waste System |
| System Description: | 38-30-00 - Waste |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
The Envirovac Toilet does not flush upon Flush Switch Actuation.
Possible Causes:
- External Service Door Indication System
- Flush Control Unit (FCU)
- Vacuum Generator (B550)
- Vacuum Generator Relay (K600)
- Flush Switch
- Logic Control Module (LCM)
- Vacuum Switch
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
NOTES:
- Refer to the EnviroVac system leak check document.
Quick Links:
| Removal of the Vacuum Pump | AMM 38-32-09-000-801 [ G5000 ] [ Global XRS ] |
| Installation of the Vacuum Pump | AMM 38-32-09-400-801 [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check the Maintenance, Service button on the CES page to confirm the status of the external service door. Is the door sensed open?
- If NO, go to step 3.
- If YES, continue with next step.
- Perform a visual inspection of the external service door. Is the door open?
- If YES, close it and do close out.
- If NO, troubleshoot the external service door indication system and do close out.
- Verify the color of the flush switch:
- If the switch is AMBER (flushing), go to step 5.
- If the switch is RED (inop), go to step 6.
- If the flush switch is not lit, go to step 7.
- If the switch is GREEN (ready), continue with next step.
- Disconnect the toilet Flush Control Unit (FCU) P2 connector, press the flush switch, perform the continuity check as follows:
From To Result P2-3 P2-5 - If there is continuity, replace FCU or toilet assembly and do close out.
- If there is no continuity, replace the flush switch and do close out.
- Cycle the toilet CB, if still amber, disconnect the FCU P2 and ensure that you have an open circuit with the switch not pressed as follows:
From To Expected Result Result P2-3 P2-5 Open - If there is continuity, replace defective switch and do close out.
- If there is no continuity, replace FCU or toilet assembly and do close out.
- Check Galley touchscreen, maintenance, diagnostic for any waste system related fault.
- If faults are displayed, refer to SmartFix Plus troubleshooting by observed fault chapter 44 and do close out.
- If no faults are displayed, continue with next step.
- Verify the logic control module (LCM) status lights.
- If the status lights are lit, go to step 9.
- If the status lights are not lit, continue with next step.
- Check LCM power with a lamp test. Is the LCM powered?
- If NO, troubleshoot power source (DCPDE 4) and do close out.
- If YES, continue with next step.
- Check power to the flush control Unit on P2-4.
- If power is present, replace FCU or toilet assembly and do close out.
- If power is not present, continue with next step
- Perform wiring check between LCM and FCU.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, replace LCM and continue with next step.
- Pull the manual flush handle and push back, was there vacuum?
- If vacuum is present, replace the toilet Assy and do close out.
- If vacuum is not present, continue with next step.
- Disconnect the vacuum generator B550P1. Verify for 115 VAC on each phase.
- If power is present on all 3 phases, replace the vacuum generator and do close out.
- If power is missing or low on one or more phase, continue with next step.
- Gain access to the Vacuum generator relay, located in baggage area under floor 252DRF close to the ACPDE 3. With the cabin powered, ensure you have power on X1 and a good ground on X2.
- You have good power on X1 and ground on X2, go to step 18.
- No power on X1, troubleshoot the power source per SWM and continue with next step.
- No ground on X2, continue with next step.
- Gain access to the vacuum switch S690, in the aft lavatory. Disconnect S690P1, perform the continuity check as follows:
From To Result S690P1-B S690P1-C - If there is no continuity, replace the switch and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result S690P1-B Ground - If there is continuity, continue with next step.
- If there is no continuity, Repair wiring or replace switch as required.
- Perform wiring check between S690 and K600.
- If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, continue with next step.
- Perform a continuity check of the aft lav servicing panel switch S84 with the door closed as follows:
From To Result S84-4 S84-6 - If there is no continuity, repair defective switch and do close out.
- If there is continuity, continue with next step.
- Check power input to K600 on A1 (W), B1 (B), and C1 (O).
- If there is power input, do close out.
- No input, continue with next step.
- If you have 115 VAC, verify the output on A2, B2 and C2.
- Perform wiring check between K600 and ACPDE 3.
- If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, troubleshoot power source and continue with next step.
- Perform the 115 VAC voltage check at K600 and verify the output on A2, B2 and C2.
- If no output at K600 A2, B2 and C2, go to step 22.
- If you have output at K600 A2, B2 and C2, continue with next step.
- Perform the wiring check between K600 and Vacuum generator.
- If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, continue with next step.
- Replace K600.
- Do close out.