Message Overview:
Message Name:
WASTE TANK QTY READINGS ERRATIC OR SENSOR FAIL MESSAGE ON GALLEY TOUCH SCREEN
| Message Code: | 383OBS003 |
| Effectivity: | All |
| System: | Water/Waste System |
| System Description: | 38-30-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
Waste Disposal Tank quantity level reading is erratic and/or SENSOR FAIL message is displayed on Galley Touch Screen Equipment (GTSE).
Possible Causes:
- Differential Pressure (DP) Sensor (MT550)
- Logic Control Module (LCM) (A800)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-38-0625 - Waste Tank Level DP Sensor - Fail message
Forum Articles/Infoservice/Newsletter:
- SB 700-38-5002 - Addition of heater and insulation blanket to the DP sensor of the water tank assembly
- SB 700-38-6002 - Addition of heater and insulation blanket to the DP sensor of the water tank assembly
Quick Links:
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Review the content of AW700-38-0625 and perform the recommended actions. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Perform a wiring check between the Waste Tank DP sensor and the Logic Control Module (LCM) as follows:
From To Result MT550P1-A A800P1-6 MT550P1-D A800P1-9 MT550P1-B A800P1-7 MT550P1-C A800P1-8 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the DP sensor. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the LCM.
- Do close out.