Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/01/24

Message Overview:

Message Name:

FAULT

Message Code:

B3-006292

Associated CAS:

APU GEN FAIL
(Caution)

Reporting LRU: APU GEN GCU
System Description: 24-31-00
24-61-00
24-64-00
Schematic Diagram: 24-31-10
24-61-00
Wiring Diagram: 24-31-09
24-31-17
24-64-01

Message Description:

The APU Generator Control Unit (AGCU) has failed.

Possible Causes:

  • Auxiliary Generator Control Unit (AGCU) (PCB9)
  • Auxiliary Generator Power Module (AGPM) (PCB10)
  • APU Generator (AGEN) (G3)
  • Auxiliary DC Power Center (ADCPC) (A196)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down.
  • AW300-24-0115 - Introduction of Improved Generator P/N A3579-102
  • AW300-24-0132 - Power Module (PMOD) P/N R3608-011 - Generator Failures at High Engine Speed
  • AW300-24-0137 - Y06 Electrical System Upgrade
  • AW300-24-0162 - Service Bulletin 100-24-20 - DC Power Center (DCPC) System - Inspection and Replacement of Internal Fuses in the L/H and R/H DC Power Center (DCPC)

Forum Articles/Infoservice/Newsletter: None

NOTES:

  • If all or any combination of the following MDC faults are posted at the same time, troubleshoot the MDC Fault B3-006657 first.  
    B3-007087 - FAULT [L GEN GCU]
    B3-006292 - FAULT [APU GEN GCU]
    B3-006657 - DPMS2/RPROT/WIRING FAULT [DIFF PROT SNSR
  • If the MDC is reporting multiple GEN GCU fault messages simultaneously, accompanied by a Proximity Sensing Electronics Unit (PSEU) failure, most likely B3-007551 - PSEU SYSTEM FAILURE or B3-007550 - PSEU OFF/NO OUTPUT, the ATA 32 fault(s) must be addressed first.
  • For troubleshooting purposes you may refer to the Generators Windings Values table.

Quick Links:

Standard Aircraft Configuration for Maintenance AMM 12-00-00-867-803
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801
Removal of the Main Generator AMM 24-31-05-000-801
Installation of the Main Generator AMM 24-31-05-400-801
Operational Test of the Main Generator AMM 24-31-05-710-801
Removal of the Generator Control Unit (GCU) - Primary AMM 24-31-13-000-801
Installation of the Generator Control Unit (GCU) - primary AMM 24-31-13-400-801
Removal of the Generator Power Module AMM 24-31-21-000-801
Installation of the Generator Power Module AMM 24-31-21-400-801
Removal of the DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of the DC Power Center (DCPC) AMM 24-61-01-400-801
Functional Test of the DC Power Center (DCPC) AMM 24-61-01-720-801
Standard Practices - Replace Wiring SPM20-12-00-02-01
Standard Practices - Wire Repair SPM20-12-10-02-01

Troubleshooting Recommendations:

  1. Swap the Auxiliary Generator Control Unit (PCB9) with the Right or Left Generator Control Unit (PCB6 or PCB5). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Control Unit.
      NOTE: Whilst the card is removed, inspect the card contacts and make sure they are clean and free from contamination.

  2. Swap the Auxiliary Generator Power Module (PCB10) with Right or Left Generator Power Module (PCB8 or PCB7). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator Power Module.

  3. Perform a wiring check between the APU Generator (G3) and the AUX DC Power Center (DCPC) (A196) as follows:

    From To Result
    G3P1-A A196P1-G
    G3P1-B A196P1-F
    G3P1-G A196P1-AA
    G3P1-D A196P1-K
    G3P1-F A196P1-h
    G3P1-E A196P1-H
    G3P1-L A196P1-JJ
    G3P1-M A196P1-z
    G3P1-H A196P1-D
    G3P1-J A196P1-d
    G3P1-K A196P1-E

    1. If wiring defects are found, repair defective wiring as required and do close out.
    2. If no defects are found, continue with next step.

  4. Swap the Auxiliary Generator (G3) with the Right or Left Generator (G2 or G1). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator.

  5. Replace AUX DCPC (A196).
  6. Do close out.