Message Overview:
Message Description:
The Auxiliary Power Unit Sensor DPMS 8 has detected a current imbalance between the 2 feeders.
A failure with the Auxiliary Power Unit Sensor DPMS 8 has been detected by the Aux DCPC.
NOTE: When DPMS 8 failure occurs, the APU generator will feed the LH MAIN BUS by default.
Possible Causes:
- Auxiliary Power Unit Sensor (DPMS8)
- Auxiliary Power Unit Power Feeders (SBZ0002-1 and SBZ0003-1)
- Terminal studs hardware loose
- Auxiliary Power Center (Aux DCPC) (A196)
- Right DC Power Center (RDCPC) (A36)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0024 - Electrical System - Troubleshooting Tips
- AW300-24-0137 - Y06 Electrical System Upgrade
- AW300-24-0222 - Aft Fuselage - APU Generator Power Feeder Cable Fouling Condition (20501 - 20635)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Removal of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-000-801 |
| Installation of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-400-801 |
| Removal of the Auxiliary Power Unit Sensor | AMM 24-64-17-000-801 |
| Installation of the Auxiliary Power Unit Sensor | AMM 24-64-17-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Access the APU DCPC terminal studs T34 and T36, remove hardware, clean terminal studs / lugs and reinstall hardware. Make sure terminal studs lock nuts are torqued to specs.
- Access the RH DCPC terminal studs T84 and T86, remove hardware, clean terminal studs / lugs and reinstall hardware. Make sure terminal studs lock nuts are torqued to specs.
- Access the Auxiliary Power Unit Sensor DPMS8, make sure its hardware is torqued to specs.
- Disconnect the Auxiliary Power Unit Sensor DPMS8 connector. Do visual inspection of the connector and associated wiring for any loose pins and/or damaged wire.
- If inspection is satisfying, continue with next step.
- If inspection is not satisfying, go to step 6.
- Interchange the Auxiliary Power Unit Sensor DPMS8 with Auxiliary Power Unit Sensor DPMS7. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary Power Unit Sensor.
- Replace the electrical power feeders SBZ0002-1 and SBZ0003-1. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary Power Unit Sensor.
NOTE: Harness assembly PN 1009109786-001 includes both power feeders and wire SBZ0001-1. SBZ0001-1 can also be replaced at your convenience.
- Replace the Aux DCPC (A196). Is the fault message still present?
- If YES, continue with next step.
- If NO, go to step 8.
- Replace the R DCPC (A35).
- Do close out.