01/20/25
Message Overview:
Message Name:
FAULT
Message Code:
B3-226910
Associated CAS:
| Reporting LRU: | R APU GEN CNTOR2 |
| System Description: | 24-31-00 - Primary DC Power System 24-64-00 - Auxiliary DC Power Center |
| Schematic Diagram: | 24-31-10 - Auxiliary DC-Power System 24-61-00 - DC Power Center (DCPC) System |
| Wiring Diagram: | 24-31-09 - APU Generator - ALL 24-64-01 - Auxiliary DC Power Center (Aux DCPC) -ALL |
Message Description:
The Right APU Generator Contactor 2 (RAPC2) has failed.
Possible Causes:
- Right Auxiliary DC Power Contactor (RAPC2) (K148)
- Auxiliary Power Center Primary Logic (ALOG) (PCB11)
- Auxiliary Power Center (Aux DCPC) (A196)
- Right DC Power Center (R DCPC) (A36)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0024 - Electrical System - Troubleshooting Tips
- AW300-24-0137 - Y06 Electrical System Upgrade
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic-Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 |
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Functional Test of the DC Power Center (DCPC) | AMM 24-61-01-720-801 |
| Removal of the Auxiliary Power Contactor | AMM 24-61-13-000-801 |
| Installation of the Auxiliary Power Contactor | AMM 24-61-13-400-801 |
| Removal of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-000-801 |
| Installation of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-400-801 |
| Operational Test of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-710-801 |
| Removal of the Auxiliary Power Center Primary-Logic | AMM 24-64-13-000-801 |
| Installation of the Auxiliary Power Center Primary-Logic | AMM 24-64-13-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Disconnect the Right Auxiliary DC Power Contactor K148 (RAPC2) connector located in the R DCPC. Do visual inspection of the connector and associated wiring for any loose pins and/or damaged wire.
- If inspection is satisfying, continue with next step.
- If inspection is not satisfying, go to step 8.
- Do wiring check of the following wire:
From To Results AUX DCPC conn. A196P2 - pin g R DCPC conn. A36P5 - pin g AUX DCPC conn. A196P2 - pin E R DCPC conn. A36P5 - pin E AUX DCPC conn. A196P2 - pin F R DCPC conn. A36P5 - pin F AUX DCPC conn. A196P2 - pin B R DCPC conn. A36P5 - pin B - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair wiring.
- Do wiring check of the following wire:
From To Results R DCPC conn. A36J5 - pin g K148 conn (P-side) - pin 6 R DCPC conn. A36J5 - pin E K148 conn (P-side) - pin 1 R DCPC conn. A36J5 - pin F K148 conn (P-side) - pin 3 R DCPC conn. A36J5 - pin B K148 conn (P-side) - pin 2 - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, go to step 8.
- Verify Right Auxiliary DC Power Contactor K148 (RAPC2) coils by measuring the resistances at the contactor connector (P-side) as per the following table:
Coils Expected Values Results (Pick-up) Pin 1 and Pin 2 between 4.5Ω and 6.5Ω (Hold) Pin 2 and Pin 3 between 260Ω and 280Ω - If the verification is satisfying, continue with next step.
- If the verification is not satisfying, replace the defective Auxiliary DC Power Contactor.
NOTE: It is important to not skip this verification before proceeding with the interchange at step 5. A short of one of the 2 coils will result with a blowing of a fuse on the Auxiliary Power Center Primary Logic PC11.
- Interchange the Right Auxiliary DC Power Contactor K148 (RAPC2) with the Left Auxiliary DC Power Contactor K149 (LAPC2). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary DC Power Contactor.
- Replace the Auxiliary Power Center Primary Logic PC11. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Aux DCPC. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Right DCPC.
- Do close out.