Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/25/25

Message Overview:

SLAT FLAP BIT
(Advisory)

GO/NO GO/RETURN TO RAMP Go
CAS MMEL RELIEF Yes
DDG Reference: None
Pilot Action (QRH): ADVISORY 7-3 [ Global Express ]  [ G5000 ]  [ Global XRS ]
System Description: 27-50-00 - Slats And Flaps System
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

On ground only, Indicates minor failure logged by SFCU 1 or 2.

The fault codes are cleared after the associated CAIMS fault is corrected.

Possible Causes:

  • Interface systems to Slat Flap Control Unit (SFCU)
  • Slat Flap Control Unit (SFCU)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Removal of SFCU AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of SFCU AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
  2. Select related CAIMS message below: