Message Overview:
| DDG Reference: | 27-51-01 |
| Pilot Action (QRH): | ADVISORY 8-2 |
| System Description: | 27-50-00 - Slats and Flaps System |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The slats operate at half speed because of a fault condition in one channel.
Possible Causes:
- One Slat Flap Control Unit (SFCU) (internal fault)
- Single channel failure at one of the Slats Wingtip Position (resolver)
- Single channel failure at one of the Slats Asymmetry Brakes
- Single failure of one of the Slats Motor/Brake Modules
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0373 - SFCU -17: "SLAT-FLAP HALFSPD" EICAS Nuisance Message
- AW700-27-0631 - Slat/Flap HALFSPEED Messages - Intermittent Slat/Flap Resolver
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter:
- Customer Forum Newsletter 2016-06-01 - Slat Flap Control System Troubleshooting
Flight Operation Notifications Manual (FONM):
- [ Global Express ] [ G5000 ] [ Global XRS ] FON 01-11 FCLT-005, [SLAT_FLAP HALFSPD] (Advisory/Cyan) or [FLAP HALFSPD] or [SLAT HALFSPD] (Advisory/Cyan) On Ground
NOTES:
- To avoid the display of any Slat/Flap related CAS nuisance message after replacement of SFCU due to internal failure, follow AW700-27-0373 instructions.
- Execute two consecutive Slats and Flaps electrical rigging per AMM 27-51-05-820-801 (All EICAS messages and CAIMS Active faults related to the Slat Flap Control System must be disregarded throughout the dual electrical CAIMS rigging process.)
- Once the two CAIMS SFCS rigging are completed, perform a complete aircraft power shut down.
- If an SFCU seems to be in a locked up state, please refer to this Troubleshooting Tip.
Quick Links:
| Electronic Rigging of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Slat Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Slat Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Flap Power Drive Unit (PDU) Motors | AMM 27-52-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Flap Power Drive Unit (PDU) Motors | AMM 27-52-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Wing Asymmetry Brake | AMM 27-52-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Wing Asymmetry Brake | AMM 27-52-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Flap Resolvers | AMM 27-52-49-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Flap Resolvers | AMM 27-52-49-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below:
- Do the close out.