02/16/21
Message Overview:
Message Name:
[ACSC1-A] FWD TRIM AIR VLV CMD /TAV
Message Code:
2161323ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The FWD Trim Air Valve (TAV) (L18) position does not agree with the Air Conditioning System Controller (ACSC) 1 command.
Possible Causes:
- FWD Trim Air Valve (TAV) (L18)
- Junction Box (JB5)
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
- Air Conditioning System Controller (ACSC) 1 (A87)
- Bleed Air Control Panel (AP8)
- Trim Air Switch (SDS6)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Trim Air Valves | AMM 21-60-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Trim Air Valves | AMM 21-60-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB5 | AMM 24-00-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB5 | AMM 24-00-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Interchange FWD Trim Air Valve with AFT Trim Air Valve.
- If the system checks are good, replace FWD Trim Air Valve and do close out.
- If the fault remains, continue with next step.
- Interchange SPDA 2 with SPDA 3.
- If the system checks are good, replace SPDA 2 and do close out.
- If the fault remains, continue with next step.
- Interchange ACSC 1 with ACSC 2.
- If the system checks are good, replace ACSC 1 and do close out.
- If the fault remains, continue with next step.
- Perform continuity check of JB5.
- If there is continuity, continue with next step.
- If there is no continuity, replace JB5 and do close out.
- Check K9 and K22 for correct operation.
- Perform a wiring checks of wires between FWD TAV and JB5.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Perform a wiring check of wires between JB5 and ACSC1.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Perform a wiring check of wires between JB5 and Bleed Air Control Panel TRIM AIR SWITCH.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Check Trim Air Control Panel.
- Replace Bleed Air Control Panel.
- Do close out.