Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/10/25

Message Overview:

Message Name:

[ACSC1-A] AFT DUCT OVERHEAT

Message Code:

2161518ECS

Associated CAS:

TRIM AIR FAIL
(Caution)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-60-00 - Temperature Control
Schematic Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control Schematic
Wiring Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System 9004 - 9010
Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System 9011 - 9027
Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System 9028 - 9059
Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System 9003, 9060-9094
Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System 9095 - 9158
[ Global Express ]  [ G5000 ]  [ Global XRS ]  21-60-00 - Temperature Control System

Message Description:

The Aft Cabin Duct has been detected in overheat condition by the left Air Conditioning Controller (ACSC) 1.

Possible Causes:

  • Air Conditioning System Controller 1 (A87)
  • Duct Temperature Sensor (DTS) 2 (E22)
  • Aft Ventilated Temperature Sensor (B16)
  • Aft Trim Air Valve (TAV) (L19)
  • Junction Box (JB5)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Removal of the Duct Temperature Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-17-000-801
Installation of the Duct Temperature Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-17-400-801
Removal of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-000-801
Installation of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-400-801
Removal of the Ventilated Temperature Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-25-000-801
Installation of the Ventilated Temperature Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-25-400-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
Removal of the Junction Box JB5 [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-09-000-801
Installation of the Junction Box JB5 [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-09-400-801
Removal of the Secondary-Power Distribution Assembly Tray [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-62-01-000-802
Installation of the Secondary-Power Distribution Assembly Tray [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-62-01-400-802
Removal of the BLEED-AIR Control Panel [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-57-000-801
Installation of the BLEED-AIR Control Panel [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-57-400-801

Troubleshooting Recommendations:

  1. Select the Aux Press Switch (SDS7) from the Bleed Air Control Panel to ON and then to OFF. Make sure the aft TAV go full open and full close according to the switch position (refer to Air Conditioning synoptic page).
  2. Interchange aft TAV with fwd TAV.

    1. If system checks are good, replace aft TAV and perform step 1 again.
    2. If fault remains, continue with next step.

  3. Perform a wiring checks between Bleed Air Control Panel Aux Press Switch (SDS7) and JB5.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  4. Perform continuity check of JB5.

    1. If there is no continuity, replace JB5 and do close out.
    2. If there is continuity, continue with next step.

  5. Perform a wiring checks between JB5 and aft TAV including the ground.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  6. Make sure power from SPDA 2 is received at JB5.
  7. Perform a wiring checks between SPDA 2-A14P4-C and JB5.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  8. Perform continuity check of JB5 as per wiring check.

    1. If there is no continuity, replace JB5 and do close out.
    2. If there is continuity, continue with next step.

  9. Perform a wiring checks between ACSC 1 and aft duct temp sensor (DTS).

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  10. Perform a wiring checks between ACSC 1 and aft Vent Sensor.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  11. Check the status of the aft DTS in CAIMS. (CAIMS path: SYS DIAG/AIR CONDITIONING/ACSC1-A/LRU TEST/L-R ACSC-A CONTROL DITRIBUTION DATA).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  12. Swap the DTS 2 with DTS 1.

    1. If system checks are good, replace DTS 2 and do close out.
    2. If fault remains, continue with next step.

  13. Check the status of the aft VENTS in CAIMS. (CAIMS path: SYS DIAG/AIR CONDITIONING/ACSC1-A/LRU TEST/L ACSC-A TRIM CABIN TEMP SENSOR DATA).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  14. Swap the aft VENT with fwd VENT.

    1. If system checks are good, replace aft VENT and do close out.
    2. If fault remains, continue with next step.

  15. Perform a wiring checks between ACSC 1 and JB5-K2.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  16. Perform continuity check of JB5.

    1. If there is no continuity, replace JB5 and do close out.
    2. If there is continuity, continue with next step.

  17. Replace ACSC 1.
  18. Do close out.