background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/10/19

Message Overview:

Fault Message:

[ACSC1-B] AFT DUCT TEMP SENS /WRG

Fault Code:

2162427ECS

Associated CAS:

TRIM AIR FAULT
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-60-00
Schematic Diagram: 21-60-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Aft Cabin Duct Temperature Sensor has been detected out of range by Air Conditioning System Controller (ACSC) 1 Channel B.

Possible Causes:

  • AFT Cabin Duct Temperature Sensor (E21)
  • Air-Conditioning System Controller (ACSC) 1 (A87)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Duct Temperature Sensors AMM 21-60-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Duct Temperature Sensors AMM 21-60-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap Aft Cabin Duct Temperature Sensor with Fwd Cabin Duct Temperature Sensor.

    1. If the system checks are good, replace Aft Cabin Duct Temperature Sensor and do close out.
    2. If the fault remains, continue with next step.

  2. Perform wiring checks between the Aft Cabin Duct Temperature Sensor and ACSC 1.

    1. If the wiring checks are not good, repair the defective associated wiring and do close out.
    2. If the wiring checks are good, continue with next step.

  3. Replace ACSC 1.
  4. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.