Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

05/05/25

Message Overview:

Message Name:

[ACSC2-A] RH FAN AIR VLV CMD /WRG

Message Code:

2163318ECS

Reporting LRU: Air Conditioning System Controller 2 (ACSC)
Associated CAS: TRIM AIR FAIL (Caution)
System Description: 21-54-00 - Avionics Cooling System
Schematic Diagram: [ G5000 ]  [ Global Express ]  [ Global XRS ] SSM 36-11-00-101 - Bleed Air System - Electrical Schematic
Wiring Diagram: [ G5000 ]  [ Global Express ]  [ Global XRS ] WM 21-52-00-4_002 - Sheet 2 - Cooling (Right) - [9090-9158]
[ G5000 ]  [ Global Express ]  [ Global XRS ] WM 21-52-02-1_001 - Sheet 1 - Cooling (Right) - ALL

Message Description:

The Fan Air Valve (FAV) is detected fail if one of the following conditions is met:

  • Fail close if the Pneumatic Temperature Thermostat (THC) send an opening command to FAV and FAV remain close
  • Fail close if Pack Inlet Temperature (PIT) > 232°C for 30 seconds
  • Fail close if PIT > 260°C for 10 seconds
  • Fail open if PIT < 150°C

Possible Causes:

  • Air Conditioning System Controller 2 (ACSC) (A88)
  • Fan Air Valve 2 (FAV) (L28)
  • Pneumatic Temperature Thermostat 2 (THC) (S13)
  • Pneumatic Temperature Thermostat (THC) Filter
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Grounding of the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM10-11-00-867-801
Removal of the Covers and Plugs [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM10-12-00-020-801
Installation of the Covers and Plugs [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM10-12-00-420-801
Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Aircraft Walkaround (for Maintenance) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-802
Removal of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-000-801
Installation of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-400-801
Operational Test of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-710-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Remove the Electrical Power from the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-802
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
Removal of the Fan Air Valve [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-17-000-801
Installation of the Fan Air Valve [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-17-400-801
Operational Test of the Fan Air Valve [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-17-710-801
Removal of the Temperature Control Thermostat [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-000-801
Installation of the Temperature Control Thermostat [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-400-801
Removal of the Temperature Control Thermostat Filter [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-000-802
Installation of the Temperature Control Thermostat Filter [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-400-802
Access to Active Faults [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-802
Access to Stored Faults [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-803
Access to System Diagnostics [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-804
Flight Deck Effect to Fault Correlations [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-821
Wire Repair - Maintenance Practices - ALL [ G5000 ]  [ Global Express ]  [ Global XRS ] SPM20-12-10-02

Troubleshooting Recommendations:

  1. Inspect, clean or replace the THC filters.
  2. Perform leak check of the sense line between THC and FAV.
  3. Interchange THC 2 with THC 1.

    1. If the system checks are good, replace THC 2 and do close out.
    2. If the fault remains, continue with next step.

  4. Interchange FAV 2 with FAV 1.

    1. If the system checks are good, replace FAV 2 and do close out.
    2. If the fault remains, continue with next step.

  5. Perform a wiring checks of the wire between ACSC and THC.

    1. If wiring checks are not good, repair defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  6. Replace ACSC 2.
  7. Do close out.