06/11/19
Message Overview:
Fault Message:
[ACSC2-A] EMER RAM VLV CMD /ERAV
Fault Code:
2163319ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Emergency Ram Air Valve (ERAV) has been detected open while it is not commended to opening by the Push Button Annunciator (PBA).
Or
The ERAV has been detected closed while it is commended to opening by the PBA.
Possible Causes:
- Air Conditioning System Controller (ACSC) 2 (A88)
- Bleed Air Control Panel (AP8)
- Data Acquisition Units (DAU) 1 (A17)
- Data Acquisition Units (DAU) 2 (A18)
- Emergency Ram Air Valve (ERAV) (L25)
- Secondary-Power Distribution Assembly (SPDA) 1 (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Ram Air Valve | AMM 21-53-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ram Air Valve | AMM 21-53-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the BLEED-AIR Control Panel | AMM 36-11-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the BLEED-AIR Control Panel | AMM 36-11-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using CAIMS, under LRU test, look at the discrete inputs for DAU 1. Make sure RAV Open (D21) and RAV Close (D28) are in accordance with the RAV switch position. Then Select RAV to On. Make sure the Status change accordingly.
- If it is not satisfactory, then continue with next step.
- If it is satisfactory, go to step 9.
- Perform a wiring checks between RAV and DAU 1.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring checks between RAV and Bleed Air Control Panel.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring checks of the Control Panel itself and its grounds.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring checks of the RAV ground.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Make sure power is available from SPDA 1.
- Swap DAU 1 with DAU 3.
- If the system checks are good, replace DAU 1 and do close out.
- If the fault remains, continue with next step.
- Replace RAV.
- If the system checks are good, do close out.
- If the fault remains, continue with next step.
- Using CAIMS, under LRU test, look at the discrete inputs for DAU 2. Make sure Ram Air On Selected show position in accordance with the switch selection. Then Select RAV to On. Make sure the Status changes accordingly.
- If it is not satisfactory, continue with next step.
- If it is satisfactory, go to step 13.
- Perform a wiring checks of the wires between DAU 2 and Bleed Air Control Panel AP8.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring checks of the Control Panel itself and its grounds.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Swap DAU 2 with DAU 4.
- If the system checks are good, replace DAU 2 and do close out.
- If the fault remains, continue with next step.
- Using CAIMS, under LRU test, look at the discrete inputs for ACSC 2. Make sure RAV show "Close". Then Select RAV to On. Make sure the Status changes to "Open".
- If it is not satisfactory, continue with next step.
- If it is satisfactory, do close out.
- Perform a wiring checks of the wires between ACSC 2 and Bleed Air Control Panel AP8.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring checks of the Control Panel itself and its grounds.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Replace ACSC 2.
- Do close out.