Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/12/19

Message Overview:

Fault Message:

[ACSC2-A] RH RECIRCUL FAN /WRG

Fault Code:

2163528ECS

Associated CAS:

RECIRC FAN FAIL
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 2
System Description: 21-60-00
Schematic Diagram: 21-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-21-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Right Recirculation Fan has been detected failed by the Right Air Conditioning Controller (ACSC).

Possible Causes:

  • Air Conditioning System Controller (ACSC) 2 (A88)
  • AC Power Center (ACPC) (A54)
  • Recirculation Fan and Check Valve 2 (B21)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)

Forum Articles/Infoservice/Newsletter: None

CAIMS has Pack Temp. Sensor Data for ACSC controllers on all 4 channels. This will show sensor data and give you an idea of problem areas, even with the air system not operating, but power is on.

Quick Links:

Removal of the Recirculation Fan and Check Valves AMM 21-21-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Recirculation Fan and Check Valves AMM 21-21-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Make sure the recirculation fan is not obstructed.
  2. Perform wiring checks between ACSC 2 and Right Recirculation Fan.

    1. If wiring checks are not good, repair defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  3. Perform wiring checks between Right Recirculation Fan and ACPC.

    1. If wiring checks are not good, repair defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  4. Swap Recirculation Fan 2 with Recirculation Fan 1.

    1. If the system checks are good, replace Recirculation Fan 2 and do close out.
    2. If the fault remains, continue with next step.

  5. Replace ACSC 2.
  6. Do close out.