Message Overview:
Fault Message:
HCU PIN PROGRAMMING INVALID
Fault Code:
2163618ECS
Associated CAS:
| Reporting LRU: | Air-Conditioning System Controller (ACSC) 2 |
| System Description: | 21-71-00 |
| Schematic Diagram: | 21-71-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-71-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Air-Conditioning System Controller (ACSC) 2 does not recognize the pin programming for the Humidifier option.
Possible Causes:
- Ground Stud (GS257)
- Air-Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a wiring check between ACSC2 A88P1-10 and GS257.
- If wiring checks are not good, repair the defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Make sure GS257 is properly installed.
- Replace ACSC2.
- Do close out.
NOTE: Perform Functional Test of the Humidifier System to confirm the system integrity. This task is the approved Return to Service (RTS) Test for the Humidifier System.
If the operator which to operate the humidifier on the ground as it operates in flight, then use the following attached procedure. Please note that the attached procedure is not approved for RTS and can only be used for troubleshooting purpose. Please note that the 3.5 hours delay can not be bypassed in this procedure.
Humidifier Operation with Aircraft W off W (3.5 hours delay activation).