Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/12/19

Message Overview:

Fault Message:

HUMID TRIM AIR VALVE (H_TAV)/ WRG

Fault Code:

2163623ECS

Associated CAS:

HUMIDIFIER FAIL
(Advisory)

Reporting LRU: Humidifier Control Unit (HCU)
System Description: 21-71-00
Schematic Diagram: 21-71-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-71-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Humidifier Control Unit (HCU) has detected that the position of the H_TAV does not agree with the command signal.

  • The humidifier boiler temperature is >130°C for more than 180 seconds
  • The humidifier boiler temperature is >140°C for more than 60 seconds

Possible Causes:

  • Humidifier Trim Air Valve (H_TAV)
  • Humidifier Control Unit (HCU) (A248)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Functional Test of the Humidifier System AMM 21-71-00-720-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Humidifier Control Unit AMM 21-71-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Humidifier Control Unit AMM 21-71-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Hot-Air Shutoff Valve AMM 21-71-41-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Hot-Air Shutoff Valve AMM 21-71-41-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform a wiring check between HCU and H_TAV including H_TAV ground.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  2. Using ATP mode, send commands to open and close the H_TAV. Make sure the H_TAV open and close as commanded (Refer to the Functional Test of the Humidifier System (TASK 21−71−00−720−801) to access ATP mode and command H_TAV to the open and close position).
  3. If needed the H_TAV can be swapped with one of the Air conditioning system HASOV.
  4. Replace H_TAV.

    1. If the system check is good, do close out.
    2. If the fault remains, continue with next step.

  5. Replace HCU.
  6. Do close out.

NOTE: Perform Functional Test of the Humidifier System to confirm the system integrity. This task is the approved Return to Service (RTS) Test for the Humidifier System.

If the operator which to operate the humidifier on the ground as it operates in flight, then use the following attached procedure. Please note that the attached procedure is not approved for RTS and can only be used for troubleshooting purpose. Please note that the 3.5 hours delay can not be bypassed in this procedure.

Humidifier Operation with Aircraft W off W (3.5 hours delay activation).