Message Overview:
Fault Message:
HUMIDIFIER WATER SOV (HWSOV)/ WRG
Fault Code:
2163625ECS
Associated CAS:
| Reporting LRU: | Humidifier Control Unit (HCU) |
| System Description: | 21-71-00 |
| Schematic Diagram: | 21-71-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-71-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Humidifier Water Shut-off Valve (HWSOV) has been detected defective by the Humidifier Control Unit (HCU).
- The humidifier boiler temperature is >130°C for more than 180 seconds
- The humidifier boiler temperature is >140°C for more than 60 seconds
Possible Causes:
- Humidifier Control Unit (HCU) (A248)
- Humidifier Water Shut-off Valve (HWSOV) (L51)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Functional Test of the Humidifier System | AMM 21-71-00-720-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Water Shutoff-Valve | AMM 21-71-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Water Shutoff-Valve | AMM 21-71-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Humidifier Control Unit | AMM 21-71-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Humidifier Control Unit | AMM 21-71-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a wiring check between HCU and HWSOV including ground.
- If wiring checks are not good, repair the defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Using ATP mode, send a command to open the HWSOV. Make sure 28 VDC is present at the HWSOV connector (Refer to the Functional Test of the Humidifier System to access ATP mode and command HWSOV to the open position).
- Replace HWSOV.
- If the system check is good, do close out.
- If the fault remains, continue with next step.
- Replace HCU.
- Do close out.
NOTE: Perform Functional Test of the Humidifier System to confirm the system integrity. This task is the approved Return to Service (RTS) Test for the Humidifier System.
If the operator which to operate the humidifier on the ground as it operates in flight, then use the following attached procedure. Please note that the attached procedure is not approved for RTS and can only be used for troubleshooting purpose. Please note that the 3.5 hours delay can not be bypassed in this procedure.
Humidifier Operation with Aircraft W off W (3.5 hours delay activation).