Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/12/19

Message Overview:

Fault Message:

HCU INTERNAL FAULT

Fault Code:

2163627ECS

Associated CAS:

HUMIDIFIER FAIL
(Advisory)

Reporting LRU: Humidifier Control Unit (HCU)
System Description: 21-71-00
Schematic Diagram: 21-71-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-71-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

An Internal Fault has been detected inside the Humidifier Control Unit (HCU).

Possible Causes:

  • Humidifier Control Unit (HCU) (A248)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Functional Test of the Humidifier System AMM 21-71-00-720-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Humidifier Control Unit AMM 21-71-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Humidifier Control Unit AMM 21-71-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Replace HCU.
  2. Do close out.

NOTE: Perform Functional Test of the Humidifier System to confirm the system integrity. This task is the approved Return to Service (RTS) Test for the Humidifier System.

If the operator which to operate the humidifier on the ground as it operates in flight, then use the following attached procedure. Please note that the attached procedure is not approved for RTS and can only be used for troubleshooting purpose. Please note that the 3.5 hours delay can not be bypassed in this procedure.

Humidifier Operation with Aircraft W off W (3.5 hours delay activation).