06/13/19
Message Overview:
Fault Message:
[ACSC2-B] CKPT DUCT TEMP SENS /WRG
Fault Code:
2164427ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Cockpit Duct Temperature Sensor detected out of range by Air Conditioning System Controller (ACSC) 2 Channel B.
Possible Causes:
- Cockpit Duct Temperature Sensor (E28)
- Air Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Duct Temperature Sensors | AMM 21-60-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Duct Temperature Sensors | AMM 21-60-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS ASCA#2A or 2B, Trim & Cabin Temp Sensor Data.
- Review cockpit sensor value.
- Swap Cockpit Duct Temperature Sensor with Cabin Duct Temp Sensor.
- If system checks are good, replace the Cockpit Duct Temperature Sensor and do close out.
- If fault remains, continue with next step.
- Perform a wiring checks between Cockpit Duct Temperature Sensor and ACSC 2.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Replace ACSC 2.
- Close out.