Message Overview:
Message Name:
APU GEN SHORTED MEF FAULT
Message Code:
2420099LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit Generator Control Unit (APU GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Auxiliary Power Unit Generator Control Unit (APU GCU) has detected a failure related to the generator shorted MEF (exciter field) wiring and consequently the Auxiliary Power Unit (APU) Generator trips off-line.
Possible Causes:
- Auxiliary Power Unit (APU) Generator (A110)
- Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap the GCU 1, the GCU 4 and the APU GCU into position 2 or 3 (for troubleshooting only). You can monitor the GCU fault in CAIMS via the active faults page.
Quick Links:
| Removal of the APU Generator | AMM 24-22-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Generator | AMM 24-22-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap the APU GCU with the GCU#2 (physically or using the GCU patch cable).
- If system checks are good, replace APU GCU and do close out.
- If fault remains, continue with next step.
- Disconnect connector A109P1 (APU GCU) and A110P1 (APU GEN).
- Perform wiring checks between A110P1-H, A110P1-B and ground.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between APU GCU (A109P1) and APU Generator (A110P1).
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Replace APU Generator.
- Do close out.