Message Overview:
Message Name:
APUGCU [VOLTAGE REGULATOR LOW]
Message Code:
2420107LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) Generator Control Unit (GCU) |
| System Description: | 24-22-00 - Auxiliary AC Power Supply |
| Schematic Diagram: | SSM 24-22-00-101 - Auxiliary AC Power Supply System [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-00-01 Sheet 1 - Auxiliary AC Power Generation System - 9004-9010 [ Global Express ] [ G5000 ] [ Global XRS ] 24-22-00-02 Sheet 1 - Auxiliary AC Power Generation System - 9011-9014 [ Global Express ] [ G5000 ] [ Global XRS ] 24-22-00-03 Sheet 1 - Auxiliary AC Power Generation System - 9003, -9015-9158 [ Global Express ] [ G5000 ] [ Global XRS] 24-22-00-04 Sheet 1 - Auxiliary AC Power Generation System - 9002 [ Global Express ] [ G5000 ] [ Global XRS] 24-22-00-01 Sheet 1 - Auxiliary AC Power Generation System - [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Auxiliary Power Unit (APU) Generator Control Unit (GCU) has detected an internal failure related to the voltage regulator low circuit and consequently APU Generator trips off-line.
Possible Causes:
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- APU Generator (A110)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
- The GCU NVMs can only be downloaded at position #2 or #3.
- A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU4 and APU GCU into position 2 or 3 (for troubleshooting only)
Quick Links:
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Aircraft Walkaround (for Maintenance) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-802 |
| Connect Electrical Power to the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-801 |
| Remove the Electrical Power from the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-802 |
| Electrical/Electronic Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-802 |
| Removal of the APU Generator | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-22-01-000-801 |
| Installation of the APU Generator | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-22-01-400-801 |
| Operational Test of the APU Generator | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-22-01-710-801 |
| Removal of the Generator Control Units (GCU) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-24-01-000-801 |
| Installation of the Generator Control Units (GCU) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-24-01-400-801 |
| Operational Test of the Generator Control Units (GCU) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-24-01-710-801 |
| Access to Active Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-802 |
| Access to Stored Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-803 |
Troubleshooting Recommendations:
- Remove power from the A/C completely. Apply power back on the A/C and access CAIMS Fault Messages. Is the CAIMS message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange AP GCU with GCU 1. Is the fault still present?
- If NO, replace APU GCU and do close out.
- If YES, continue with next step.
- Disconnect APU Generator connector (A110P1), ACPC connector (A54P4) and APU GCU connector (A109P1). Perform a continuity check as follows:
From To Result A109P1-J Ground A109P1-K Ground A109P1-A Ground A109P1-B Ground A109P1-C Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A109P1-J A110P1-H A109P1-K A110P1-B A109P1-A A54P4-A A109P1-B A54P4-B A109P1-C A54P4-C - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- At APU Generator, disconnect G terminal.
- Perform a continuity check on aircraft wiring side as follow:
From To Result APU G - G Ground - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace APU Generator (A110).
- Do close out.