Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/14/19

Message Overview:

Fault Message:

APU GEN OPEN POR/FEED/GEN FAULT

Fault Code:

2420108LPS

Associated CAS:

APU GEN FAIL
(Advisory)

Reporting LRU: Auxiliary Power Unit (APU) Generator Control Unit (GCU)
System Description: 24-22-00
Schematic Diagram: 24-22-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-22-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Auxiliary Power Unit (APU) Generator has tripped off-line or will not come on-line.

Possible Causes:

  • Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
  • Auxiliary Power Unit (APU) Generator (A110)
  • AC Power Center (ACPC) (A54)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Removal of the APU Generator AMM 24-22-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Generator AMM 24-22-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap APU GCU with GCU #2 (physically or using the GCU patch cable). Is the fault still present?

    1. If NO, replace APU GCU and do close out.
    2. If YES, continue with next step.

  2. Disconnect connector A109P1 (APU GCU) and A54P4 (ACPC). Do a continuity check as follows:

    From To Result
    A109P1-A Ground
    A109P1-B Ground
    A109P1-C Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Do a continuity check as follows:

    From To Result
    A109P1-A A54P4-A
    A109P1-B A54P4-B
    A109P1-C A54P4-C

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Do a continuity check as follows:

    From To Result
    APU GEN stud T1 ACPC stud T13
    APU GEN stud T2 ACPC stud T14
    APU GEN stud T3 ACPC stud T15

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  5. Disconnect ACPC studs T13, T14 and T15. Do a continuity check as follows:

    From To Result
    APU GEN stud T1 Ground
    APU GEN stud T2 Ground
    APU GEN stud T3 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  6. Do a continuity check on the ACPC as follows:

    From To Result
    A54J4-A Ground
    A54J4-B Ground
    A54J4-C Ground

    1. If there is continuity, go to step 8.
    2. If there is no continuity, continue with next step.

  7. Do a continuity check on the ACPC as follows:

    From To Result
    A54J4-A ACPC stud T13
    A54J4-B ACPC stud T14
    A54J4-C ACPC stud T15

    1. If there is continuity, go to step 9.
    2. If there is no continuity, continue with next step.

  8. Replace ACPC.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  9. Replace APU Generator.
  10. Do close out.