Message Overview:
Fault Message:
APU GEN/READY/FADEC FAULT
Fault Code:
2420110LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) Generator |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
CAIMS message posted normally if APU is running normally and the Auxiliary Power Unit (APU) Generator will not come on-line or has tripped off-line. 'APU GEN FAIL' CAS message will also be posted.
Possible Causes:
- Auxiliary Power Unit (APU) Variable Frequency Generator (VFG)
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- Auxiliary Power Unit (APU) Full Authority Digital Engine Controller (FADEC) (A108)
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) Primary Logic Card (PLC) 1
- AC Power Center (ACPC) Primary Logic Card (PLC) 2
- AC Power Center (ACPC) Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the APU Generator | AMM 24-22-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Generator | AMM 24-22-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the PMAT, access CAIMS Active Faults. Are there any other APU GCU or APU Generator related faults?
- If YES, troubleshoot these messages first.
- If NO, continue with next step.
- In CAIMS, select SYSTEM DIAG, ATA 49, CONTROLLER (FADEC) and make a selection of LRU TEST. Select APU STATUS. Does the GENERATOR READY TO LOAD SIGNAL show as active?
- If YES, go to step 4.
- If NO, continue with next step.
- Re-rack the APU FADEC properly. Is the fault resolved?
- If YES, do close out.
- If NO, replace APU FADEC.
- Swap APU GCU with GCU 2 or 3. Is the fault resolved?
- If YES, replace APU GCU and do close out.
- If NO, continue with next step.
- Disconnect APU FADEC connector A108BP1. Disconnect APU GCU connector A109P2. Do a continuity check as follows:
From To Result A109P2-38 Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Do a continuity check as follows:
From To Result A109P2-38 A108BP1-A4 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Access the ACPC Logic assembly. Remove PLC 1, PLC 2 and PLC 3. Do a continuity check as follows:
From To Result A109P2-58 Ground - If there is continuity, repair defective wiring as required or replace ACPC if defect is in ACPC and do close out.
- If there is no continuity, continue with next step.
- Do a continuity check as follows:
From To Result A109P2-58 P315A-7 A109P2-58 P115A-7 A109P2-58 P415A-7 - If there is no continuity, repair defective wiring as required or replace ACPC if defect is in ACPC and do close out.
- If there is continuity, continue with next step.
- Reinstall PLC 2 and PLC 3 only. Apply power to the A/C. Is the fault still present?
- If NO, replace defective PLC and do close out.
- If YES, continue with next step.
- Remove power from the A/C. Remove PLC 2 and reinstall PLC 1. Apply power to the A/C. Is the fault still present?
- If NO, replace defective PLC and do close out.
- If YES, continue with next step.
- Remove power from the A/C. Remove PLC 3 and reinstall PLC 2. Apply power to the A/C. Is the fault still present?
- If NO, replace defective PLC and do close out.
- If YES, continue with next step.
- Replace the APU VFG.
- Do close out.