Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/18/19

Message Overview:

Fault Message:

APU GEN OVERCURRENT FAULT

Fault Code:

2420115LPS

Associated CAS:

APU GEN FAIL
(Advisory)

Reporting LRU: Auxiliary Power Unit (APU) Generator Control Unit (GCU)
System Description: 24-22-00
Schematic Diagram: 24-22-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-22-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Auxiliary Power Unit (APU) Generator Control Unit (GCU) has reported an over current on one phase of the APU Generator.

Possible Causes:

  • Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
  • Auxiliary Power Unit (APU) Generator (A110)
  • AC Power Center (ACPC) (A54)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Over-current detection specification:

  • The output current on one phase of the APU Generator is more than 185 Amps

Quick Links:

Removal of the APU Generator AMM 24-22-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Generator AMM 24-22-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

NOTE: Due to the nature of this CAIMS message, wiring checks should be performed prior to swapping any LRUs in order to prevent damage to LRUs or aircraft.

  1. Perform a visual inspection for arcing evidences of ACPC primary section. Focus on K1, APU Generator and APU Gen feeder cables.

    1. If arcing evidence is found, repair/replace damaged components and do close out.
    2. If fault remains, continue with next step.

  2. Perform operation test of APU generator.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Swap APU GCU with GCU#2.

    1. If system checks are good, replace APU GCU and do close out.
    2. If fault remains, continue with next step.

  4. Check for short circuit to GND at T1, T2 and T3 on APU GEN.

    1. If short circuit is found, go to step 13.
    2. If fault remains, continue with next step.
      NOTE: Disconnect the power feeder cables on studs T1, T2, T3 and the ground cable (G) for short circuit test.

  5. Perform wiring checks between ACPC, APU GCU and APU GEN.

    1. If wiring checks are not good, repair defective wiring and do close out.
    2. If wiring checks are good, continue with next step.

  6. Check for short circuit to GND between APU GCU and ACPC wiring.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.
      NOTE: Disconnect A109P1 and A54P4 for short circuit test.

  7. Check for short circuit to GND between APU GEN and ACPC wiring.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.
      NOTE: Disconnect power feeder cables on studs T1, T2, T3, T13, T14 and T15.

  8. Check for short circuit to GND between APU GEN and APU GCU wiring.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.
      NOTE: Disconnect A109P2 and A110P1 for short circuit test.

  9. Check for consistency of resistance for APU GEN coils by measuring all phases A110P1-F, A110P1-E, A110P1-J to A110P1-D (COM).

    1. If resistance is out of range, go to 13.
    2. If resistance is within range, continue with next step.

  10. Check for consistency of resistance for ACPC coils by measuring all phases A54P-F, A54P1-E, A54P1-G to A54P1-H (COM).

    1. If resistance is out of range, go to 12.
    2. If resistance is within range, continue with next step.

  11. Replace K1.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  12. Replace ACPC.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  13. Replace APU GEN.
  14. Do close out.