06/18/19
Message Overview:
Fault Message:
APU GEN [INCORRECT PHASE SEQUENCE]
Fault Code:
2420119LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) Generator |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit (APU) Generator has tripped off-line or will not come on-line.
Possible Causes:
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- Auxiliary Power Unit (APU) Generator (A110)
- AC Power Center (ACPC) (A54)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the APU Generator | AMM 24-22-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Generator | AMM 24-22-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- At the APU Generator, do a check of the output connections at the terminal block. Reconnect as required.
Connection Color T1 White T2 Blue T3 Orange G Green - If system checks are good, do close out.
- If fault remains, continue with next step.
- At the ACPC, do a check of the APU Generator output connection at the APU (no. 5) LCTA. Reconnect as required.
Connection Color T13 White T14 Blue T15 Orange - If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace APU GCU.
NOTE: Use PMAT to monitor the fault on GCU. - Do close out.