06/18/19
Message Overview:
Fault Message:
APU GEN CT OPEN/SHORT CCT FAULT
Fault Code:
2420122LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) Generator Control Unit (GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit (APU) Generator Control Unit (GCU) detects an open or short circuit condition related to the Generator Current Transformer (CT).
Possible Causes:
- Auxiliary Power Unit (APU) Generator Control Unit (GCU) (A109)
- Auxiliary Power Unit (APU) Generator (A110)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the APU Generator | AMM 24-22-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Generator | AMM 24-22-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap APU GCU with GCU #2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace APU GCU and do close out.
- If fault remains, continue with next step.
- Disconnect connector A110P1 on the APU GEN and A109P2 on the APU GCU.
- Perform wiring checks (open circuit = failure) between A110P1 and A109P2 as follow:
From To Result A110P1-F A109P2-41 A110P1-E A109P2-42 A110P1-J A109P2-50 A110P1-D A109P2-40 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks (closed circuit = failure) between A110P1 and ground as follow:
From To Result A110P1-F Ground A110P1-E Ground A110P1-J Ground A110P1-D Ground - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace APU GEN.
- Do close out.