06/20/19
Message Overview:
Fault Message:
APUGCU [GEN CURRENT LIMIT SENSE]
Fault Code:
2420196LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit Generator Control Unit (APU GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit Generator Control Unit (APU GCU) has detected an internal failure related to the generator current limit sensing circuit and, consequently resulting in Auxiliary Power Unit (APU) generator tripped off-line.
Possible Causes:
- Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The GCU NVMs can only be downloaded at position #2 or #3.
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU4 and APU GCU into position 2 or 3 (for troubleshooting only).
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |