03/19/20
Message Overview:
Fault Message:
GEN3 FIELD -VE TO GROUND FAULT
Fault Code:
2423102LPS
Associated CAS:
| Reporting LRU: | Variable Frequency Generator (VFG) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Variable Frequency Generator (VFG) 3 has tripped off-line or will not come on-line. There is a short circuit to ground at the field negative of the No. 3 main generator.
Possible Causes:
- Variable Frequency Generator (VFG) 3 (G3)
- Generator Control Unit (GCU) 3 (A58)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 3 with GCU 2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU. - Disconnect connector GCU 3 (A58P1) and VFG (G3P1).
- Perform wiring checks (continuity= failure) within VFG 3 as follow:
From To Result G3P1-B Ground - If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace VFG 3.
NOTE: Check G3J1-B (VFG side) is shorted to ground to confirm VFG/connector failure. - Do close out.