06/26/19
Message Overview:
Fault Message:
GEN3 OPEN CIRCUIT FIELD FAULT
Fault Code:
2423105LPS
Associated CAS:
| Reporting LRU: | Variable Frequency Generator (VFG) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Variable Frequency Generator (VFG) 3 has tripped off-line or will not come on-line.
Possible Causes:
- Variable Frequency Generator (VFG) 3 (G3)
- Generator Control Unit (GCU) 3 (A58)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU #3 with GCU #2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 3 and do close out.
- If fault remains, continue with next step.
- Disconnect connector GCU 3 (A58P1) and VFG 3 (G3P1).
- Do a resistance check (6.0 to 7.3 ohms at 20°C) on the VFG receptacle G3J1 (VFG side) as follows:
From To Result G3J1-B G3J1-H - If resistance is out of tolerance, go to step 5.
- If resistance is within tolerance, continue with next step.
- Perform wiring checks (open circuit= failure) as follow:
From To Result G3P1-H A58P1-J G3P1-B A58P1-K - If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace VFG #3.
- Do close out.