Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/26/19

Message Overview:

Fault Message:

GEN3 OPEN POR/FEED/GEN FAULT

Fault Code:

2423108LPS

Associated CAS:

GEN 3 FAIL
(Advisory)

Reporting LRU: Generator Control Unit (GCU) 3
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Generator Control Unit (GCU) 3 has detected a failure (open circuit) associated with the Open POR/FEED/GEN circuit and consequently Generator 3 trips off-line. Inhibited during Take-Off and Landing.

Possible Causes:

  • Generator Control Unit (GCU) 3 (A58)
  • Variable Frequency Generator (VFG) 3 (G3)
  • AC Power Center (ACPC) (A54)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap GCU 3 with GCU 4 (physically or using the GCU patch cable). Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace GCU 3 and do close out.

  2. Disconnect connector GCU 3 (A58P1) and ACPC (A54P3). Perform a continuity check as follows:

    From To Result
    A58P1-A Ground
    A58P1-B Ground
    A58P1-C Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Perform a continuity check as follows:

    From To Result
    A58P1-A A54P3-A
    A58P1-B A54P3-B
    A58P1-C A54P3-C

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  4. Perform a continuity check as follows:

    From To Result
    VFG 3 Stud T1 ACPC VFG 3 Stud T7
    VFG 3 Stud T2 ACPC VFG 3 Stud T8
    VFG 3 Stud T3 ACPC VFG 3 Stud T9

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  5. Disconnect ACPC studs T7, T8 and T9. Perform a continuity check as follows:

    From To Result
    VFG 3 stud T7 Ground
    VFG 3 Stud T8 Ground
    VFG 3 Stud T9 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  6. Perform a continuity check on the ACPC as follows:

    From To Result
    A54P3-A Ground
    A54P3-B Ground
    A54P3-C Ground

    1. If there is continuity, go to step 9.
    2. If there is no continuity, continue with next step.

  7. Perform a continuity check on the ACPC as follows:

    From To Result
    A54P3-A ACPC VFG 3 Stud T7
    A54P3-B ACPC VFG 3 Stud T8
    A54P3-C ACPC VFG 3 Stud T9

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  8. Swap VFG 3 with VFG 4. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace VFG 3 and do close out.

  9. Replace ACPC.
  10. Do close out.