Message Overview:
Fault Message:
GEN3 [LOW OIL PRESSURE FAULT]
Fault Code:
2423127LPS
Associated CAS:
| Reporting LRU: | Variable Frequency Generator (VFG) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Variable Frequency Generator (VFG) 3 has tripped off-line or will not come on-line.
Possible Causes:
- AC Power Center (ACPC) (A54)
- Generator Control Unit (GCU) 3 (A58)
- Variable Frequency Generator (VFG) 3 (G3)
- Variable Frequency Generator (VFG) 3 Oil Pressure Switch
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Oil Pressure Switch | AMM 24-25-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Oil Pressure Switch | AMM 24-25-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check oil quantity in VFG 3. Service/refill as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap VFG 3 oil pressure switch with VFG 4 oil pressure switch.
- If system checks are good, replace VFG 3 oil pressure switch and do close out.
- If fault remains, continue with next step.
- Swap the GCU 3 with GCU 2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 3 and do close out.
- If fault remains, continue with next step.
- Disconnect connector GCU 3 (A58P2) and VFG 3 (G3P2).
- Perform wiring checks (closed circuit= failure) within G3P2 as follow:
From To Result G3P2-A G3P2-B - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace VFG 3.
- Do close out.