Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/26/19

Message Overview:

Fault Message:

GEN3/GCU3 C PHASE PMG FAULT

Fault Code:

2423190LPS

Associated CAS:

GEN 3 FAIL
(Advisory)

Reporting LRU: Generator Control Units (GCU) 3
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Generator Control Units (GCU) 3 senses a Permanent Magnet Generator (PMG) failure on phase C.

Possible Causes:

  • Generator Control Unit (GCU) 3 (A58)
  • Variable Frequency Generator (VFG) 3 (G3)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Over current detection specification: output current is more than 185 Amps on at least one phase of the Generator 3.

Quick Links:

Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap GCU 3 with GCU 4.

    1. If system checks are good, replace GCU 3 and do close out.
    2. If fault remains, continue with next step.

  2. Perform wiring checks between GEN 3 and GCU 3 as follow:

    From To Result
    G3P1-L A58P1-G

    1. If wiring checks are not good, repair wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  3. Replace GEN 3.
  4. Do close out.