background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/27/24

Message Overview:

Fault Message:

GEN3 DRIVE SHAFT FAIL/INVALID % N2

Fault Code:

2423200LPS

Associated CAS:

GEN 3 FAIL
(Advisory)

Reporting LRU: Generator Control Units (GCU) 3
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Variable Frequency Generator (VFG) 3 has tripped off-line or will not come on-line.

Possible Causes:

  • Variable Frequency Generator (VFG) 3 (G3)
  • Generator Control Unit (GCU) 3 (A58)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-24-0598 - Variable Frequency Generator (VFG) GL511-1103-9 - Failure

Full Throttle Blog/Forum Articles/Infoservice/Newsletter:

NOTES:

  • Prior to T/S procedures, perform a visual of generator 3 for heat distress. Confirm if the heat exchanger is blocked  with FOD.
  • A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

  • The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access CAIMS and check if the following faults are active:

    • 2423126LPS - GEN3 OIL OVERTEMP FAULT
    • 2423124LPS - GEN3 [DIFF PROTECTION FEEDER]

    Inspect the VFG for the following:

    • VFG oil filter bypass indicator tripped, and/or
    • Metal particles in the oil lines, and/or
    • VFG end frame cracked or breached, and/or
    • Oil sight glass cracked

    1. If there is a combination of the listed CAIMS active fault and VFG condition(s) perform RIL GX-0198
    2. If there is NO combination, continue with next step.

  2. Do a visual inspection of VFG 3. Is the drive shaft broken or sheared?

    1. if YES, investigate the cause and replace VFG 3.
    2. If NO, continue with next step.

  3. Interchange GCU 3 with GCU 2 (physically or using the GCU patch cable).

    1. If system checks are good, replace GCU 3 and do close out.
    2. If fault remains, continue with next step.

  4. Disconnect VFG 3 connector G3P1 and GCU 3 connector A58P1. Do a continuity check as follows:

    From To Result
    A58P1-E Ground
    A58P1-F Ground
    A58P1-G Ground

    1. If there is continuity, repair defective wiring as required.
    2. If there is NO continuity, continue with next step.

  5. Do continuity check between GCU 3 and VFG 3 as follows:

    From To Result
    A58P1 -E G3P1-G
    A58P1-F G3P1-C
    A58P1-G G3P1-L

    1. If there is continuity, continue with next step.
    2. If there is NO continuity, repair defective wiring as required.

  6. Disconnect connector ACPC (A54P3) and connector GCU 3 (A58P2). Perform wiring check between GCU 3 and ACPC as follows:

    From To Result
    A58P2-9 A54P3-a
    A58P2-15 A54P3-b

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  7. Replace VFG 3.
  8. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.