06/27/19
Message Overview:
Fault Message:
GCU3 [ROTOR DIODE SENSE]
Fault Code:
2423242LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 3 has detected an internal failure related to the Rotor Diode Sensing Circuit and, consequently Generator 3 trips off-line. The Rotor Diode/Main Rotor Assembly is an integral part of the Generator and provides the excitation voltage to the Main Stator Alternator of the Generator. A failed Rotor Diode, within the Rotor Diode/Main Rotor Assembly, is indicated by excessive ripple voltage on the Generator output voltage.
Possible Causes:
- Generator Control Unit (GCU) 3 (A58)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The GCU NVMs can only be downloaded at position #2 or #3. A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 4 and APU GCU into position 2 or 3 (for troubleshooting only).
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |