Message Overview:
Fault Message:
DCPC SPDA DC BUS 2 FEEDER CARD A3
Fault Code:
2460403DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-61-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Voltage or trip status of any programmable Solid-State Power Controller (SSPC) on the Feeder Card is detected not in commanded state. Detected at power-up or continuous Built-In Test (BIT).
Possible Causes:
- DC Power Center (DCPC) (A63)
- Secondary-Power Distribution Assembly (SPDA) 1 (A13)
- DC Bus 2 Feeder Card
- Left Microprocessor Card (p/o A20)
- Right Microprocessor Card (p/o A20)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The following are the main functions of DCPC SPDA DC Bus 2 Feeder card:
- Provides for power switching and load protection for four SPDA feeders on DC bus 2
- Monitors SSPC status
- Monitors DC bus voltage status
- Monitors fuse and diode status on DC bus 2 (EM 2)
Quick Links:
| Access of Signboard Menu in EMS CDU | AMM 24-00-00-946-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Fault-Tolerant Microprocessor | AMM 24-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Fault-Tolerant Microprocessor | AMM 24-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access the Signboard menu on the EMS CDU as per AMM TASK 24-00-00-946-801. Press on the “TEST” button on EMS CDU. On the line “ASSEMBLY”, make a selection of “DCPC”. On the line “SWAP MICROPROCESSORS” make selection of swapping from one side to the other. Is the fault resolved?
- If YES, replace the now inactive microprocessor and do close out.
- If NO, continue with next step.
EMSCDU - Signboard Test Menu
- Swap SPDA DC BUS 2 FEEDER Card with SPDA DC BUS 1 FEEDER Card. Did the fault follow?
- If YES, replace SPDA DC BUS 2 FEEDER Card and do close out.
- If NO, continue with next step.
- Verify the voltage references input of the SPDA DC BUS 2 FEEDER Card. Remove the SPDA DC BUS 2 FEEDER Card, the Left Microprocessor card and the Right Microprocessor card from the DCPC. Perform a continuity check as follows:
From To Result P231A-13/14 Ground P231C-13/14 Ground P231C-16 Ground - If there is continuity, replace DCPC and do close out.
- If there is no continuity, continue with next step.
DCPC SPDA DC BUS 2 FEEDER CARD A3
- Perform a continuity check as follows:
From To Result P231A-13/14 P3A/B/C-38/39 P231C-13/14 P2A/B/C-38/39 P231C-16 P3A-46 - If there is no continuity, replace DCPC and do close out.
- If there is continuity, continue with next step.
- Replace the left Microprocessor. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Install the left Microprocessor back and replace the right Microprocessor.
- Do close out.