background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

DCPC SPDA DC BAT BUS FEEDER CARD A5

Fault Code:

2460405DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: DC Power Center (DCPC)
System Description: 24-60-00
Schematic Diagram: 24-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Voltage or trip status of any programmable Solid State Power Converter (SSPC) on the Feeder Card is detected not in commanded state. Detected at power-up or continuous Built-In Test (BIT).
DCPC SPDA DC BATT BUS FEEDER CARD A5

Possible Causes:

  • DC Power Center (DCPC) (A63)
  • DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) 1 (A13)
  • DC BATT BUS Feeder Card
  • Battery/Ram-Air Turbine Interface (BATT/RAT I/F) Card (p/o A20)
  • Right Microprocessor Card (p/o A20)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

The following are the main functions of DCPC SPDA DC BATT Bus Feeder card:

  • Provides for power switching and load protection for four SPDA feeders on DC BATT Bus
  • Monitors SSPC status
  • Monitors DC BATT bus voltage status
  • Monitors fuse and diode status on DC BATT Bus (EM 4)

Quick Links:

Access of Signboard Menu in EMS CDU AMM 24-00-00-946-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Fault-Tolerant Microprocessor AMM 24-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Fault-Tolerant Microprocessor AMM 24-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder AMM 24-61-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder AMM 24-61-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access the Signboard menu on the EMS CDU as per AMM TASK 24-00-00-946-801. Press on the "TEST" button on EMS CDU. On the line "ASSEMBLY", make a selection of "DCPC". On the line " SWAP MICROPROCESSORS" make selection of swapping from one side to the other. Is the fault resolved?

    1. If YES, replace the now inactive microprocessor and do close out.
    2. If NO, continue with next step.

  2. Swap SPDA DC BATT BUS FEEDER Card with SPDA DC BUS 1 FEEDER Card. Did the fault follow?

    1. If YES, replace SPDA DC BATT BUS FEEDER Card and do close out.
    2. If NO, continue with next step.

  3. Verify the voltage references input of the SPDA DC BATT BUS FEEDER Card A5. Remove the SPDA DC BATT BUS FEEDER Card, the right Microprocessor and the BATT/RAT Interface CONNECTORS card from the DCPC. Perform a continuity check as follows:

    From To Result
    P431A-13/14 Ground
    P431C-13/14 Ground
    P431C-16 Ground

    1. If there is continuity, replace DCPC and do close out.
    2. If there is no continuity, continue with next step.

  4. Perform a continuity check as follows:

    From To Result
    P431A-13/14 P410A/B/C-38/39
    P431C-13/14 P3A/B/C-38/39
    P431C-16 P410A-46

    1. If there is no continuity, replace DCPC and do close out.
    2. If there is continuity, continue with next step.

  5. Swap the left Microprocessor with the right Microprocessor. Is the fault resolved?

    1. If YES, replace left Microprocessor and do close out.
    2. If NO, continue with next step.

  6. Replace BATT/RAT I/F card.
  7. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.